but are not limited to, the following:
W.R. Grace and Company; Grace Construction Products.
Protecto Wrap Company.
GAF Corporation.
Henry Company.
Approved Equivalent (see Section 01630 - Products and Substitutions)
wRWN>
2.02 MATERIALS
A. Provide underlayment materials that comply with the requirements and referenced
standards.
B. Underlayment will be a cold applied, self-adnering membranes composed of a high
strength polyethylene film coated on one side with a layer of rubberized asphalt
adhesive and inter-wound with a disposable release sheet. An embossed, Slip resistant
surface is provided on the polyethylene.
C. Underlayment shall meet the physical properties and performance characteristics
indicated:
Thickness membrane: 40 mil (min)
Tensile strength, membrane ASTM D 882-02 A (Die C modified): 1400 psi.
Elongation, membrane ASTM D 412-06ael (Die C modified): 500%.
Low temperature flexibility, ASTM D 1970-08: Unaffected at -292F (-202C)
Adhesion to plywood, ASTM D 903-98(2004): 525 N/m (3 Ib/in width)
Permeance (max), ASTM E 96-05: 2.9 ng/(PA x s x m2) (0.05 perms max)
Material weight installed (max): 1.3 kg/m2 (0.3 Ib/ft2 max)
2010 Florida Building Code approved.
ONA OR WNH >
2.03 PRECAUTIONS AND LIMITATIONS
A. Installed material is slippery when wet or covered by frost.
B. Release liners are very slippery. Remove from work area immediately after membrane
application.
C. Always wear fall protection when working on roof deck.
D. Donot leave permanently exposed to sunlight. Underlayment should not be left
exposed for more than thirty (30) days.
E. Check with the manufacturer of the metal roofing system for any special requirements
when used under metal roofing. Do no install directly under roof coverings especially
sensitive to corrosion, such as zinc, and copper without providing proper ventilation.
Ce
EES "ee
PART 3 - EXECUTION
3.01 EXAMINATION
A. Examine substrates and conditions, with installer present, for compliance with the
requirements in which substrates and related work are specified and to determine if
other conditions affecting the performance of the insulation are satisfactory. Do not
proceed with the installation of the insulation, until unsatisfactory conditions have been
corrected.
3.02 INSTALLATION, GENERAL
A. Comply with the insulation manufacturer's written instructions applicable to the products
and applications indicated.
B. Install underlayment directly on a clean, dry continuous structural deck.
1. Remove dust, dirt, loose nails and excess roofing materials.
2. Protrusions from the deck area must be removed.
3. Decks shall have no voids, damaged or unsupported areas.
4. Repair deck areas before installing the membrane.
C. Apply underlayment Only in fair weather when the air, roof deck and membrane are at
temperatures of 40 degrees F or higher, and / or as recommended by the manufacturer.
D. Install the membrane so that all laps shed water. Always work from the low point to the
high point of the roof. Apply the membrane in valleys before the membrane is applied
to the eaves. Following placement along the eaves, continue application of the
membrane up the roof. The membrane shali be installed horizontally.
1. Overlaps / Side laps shall be a 4" min.
2. End laps shall be a 6" min.
E. Use smooth shank, electroplated galvanized nails with button caps for roofing fasteners.
Hand nailing will provide a better seal than power activated nailing. If nailing of the
membrane is necessary on steep slopes during hot weather, back nail and cover nails by
overlapping with the next sheet.
F. Repair holes, fish mouths, tears, and / or damage to membrane with a round patch of
membrane extending past the damaged area a min of 6" in all directions. If fasteners
are removed leaving holes in the membrane. it must be patched. The membrane may
not be self-sealing at open fastener penetrations.
END OF SECTION 07301
Page 23
SECTION 07900
JOINT SEALANTS
PART 1 - GENERAL
1.01 RELATED DOCUMENTS
A. The Drawings and general Provisions of the Contract, including General and
Supplementary Conditions and Division 1 Specification Sections, apply to this Section.
1.02 SUMMARY
A. This Section includes the following installation of the joint sealants:
1. Preparing the sealant substrate surfaces.
2. Sealant and joint backings.
B. Related Sections include the following:
1. Section 07416 - Metal Roof Panels
2. Section 07620 - Sheet Metal Flashing and Trim
1.03 REFERENCES
ASTM C 834 - Standard Specification for Latex Sealants.
ASTM C 919 - Standard Practice for Use of Sealants in Acoustical Applications.
ASTM C 920 - Standard Specification for Elastomeric Joint Seaiants.
ASTM C 1193 - Standard Guide for Use of Joint Sealants.
OUOW>
1.04 SUBMITTALS
A. Product Data: For each type of Product and material required, including product
specifications and product test reports.
1.05 QUALITY ASSURANCE
A. Perform sealant work in accordance with the sealant manufacturer's requirements for
preparation of surfaces and material installation instructions.
B. Maintain proper temperature range and humidity requirements as recommended by the
sealant manufacturer during and after the installation.
PART 2 - PRODUCTS
2.01 MANUFACTURERS
A. Available Products are Subject to compliance with the requirements, products that may
be incorporated into the Work include, but are not limited to, the following:
Dow Corning Corporation.
Pecora Corporation.
Sonneborn Building Products.
Tremco, Inc.
GE Plastics.
Approved Equivalent (see Section 01630 - Products and Substitutions)
NE IS
SaRWn>
2.02 SEALANTS
A. A. Type ES - General Purpose Exterior Sealant: Polyurethane, ASTM C920-08, Grade NS,
Class 25, Uses M, G, and A: single or multi component, chemical curing, non-
sagging, non-staining, non-bleeding, capable of continuous water immersion.
Color: Standard colors matching finished surfaces.
Elongation Capability 25 percent
Service Temperature Range -45 to 180 degrees F
Shore A Hardness Range 20 to 35
Applications / used for:
VR wWN>
a. Joints between metal frames and other materials,
b. Other exterior joints for which no other sealant is provided.
B. Type SS - Silicone Sealant: ASTM C920-08, Grade NS, Class 25, Uses NT. M, G, A & O; single
component, solvent / chemical curing, non-sagging, non-staining, non-bleeding and
mold / fungus resistant.
Color: Standard colors matching finished surfaces.
Elongation Capability 50 percent
Service Temperature Range -65 to 180 degrees F
Shore A Hardness Range 15 to 35
Applications / used for:
okWN >
a. General Purpose Exterior Sealant.
C. Type MLJ - Exterior Metal Lap Joint Sealant: Butyl or Polyisobutylene, ASTM C920-08, Grade
NS, Class 12 4%", Use NT; single component, non-drying, non-skinning, non-curing.
1. Applications / used for:
a. Concealed sealant bead in sheet metal work.
2.03 ACCESSORIES
A. Primer: Non-staining type, as recommended by sealant manufacturer to suit application.
B. Joint Cleaner; Non-corrosive and non-staining type, as recommended by the sealant
manufacturer that is compatible with the joint forming materials.
C. Joint Backing; ASTM D 1056-07, round, closed cell polyethylene foam rod, oversized 30 to
50 percent larger than the joint width.
D. Bond Breaker; Pressure sensitive tape recommended by the sealant manufacturer to suit
the application.
PART 3 - EXECUTION
3.01 EXAMINATION AND PREPARATION
A. Examine substrates and conditions, with Installer present, for compliance with the
requirements in which substrates and related work are specified and to determine if
————
IEESOOSS’”S’y'”: hhc cc rrr
other conditions affecting the performance of the joint sealants are satisfactory. Do not
proceed with the installation, until unsatisfactory conditions have been corrected.
B. Remove any loose materials and foreign matter which might impair adhesion of sealant.
C. Clean and prime joints in accordance with manufacturer's instructions and ASTM C 1193.
3.02 INSTALLATION
A. Perform work in accordance with sealant manufacturer's requirements for preparation of
surfaces and material installation instructions.
B. Comply and perform sealant installation in accordance with ASTM C 1193,
C. Measure joint dimensions and size joint backers to achieve width-to-depth ratio, neck
dimension, and surface bond area as recommended by manufacturer, except where
specific dimensions are indicated.
D. Install bond breaker where joint backing is not used.
E. Install sealant free of air pockets, foreign embedded matter, ridges, and sags.
F. Apply sealant within recommended application temperature ranges. Consult the
manufacturer when sealant cannot be applied within these temperature ranges.
G. Tool joints concave.
3.03 CLEANING
A. Clean off excess sealant or sealant smears adjacent to joints as the Work progresses by
methods and with cleaning materials approved in writing by manufacturers of joint
sealants and of products in which joints occur.
3.04 PROTECTION
A. Protect joint sealants during and after curing period from contact with any
contaminating substances and from damage resulting from construction operations or
other causes so sealants are without deterioration or damage at time of project
completion.
END OF SECTION 07900
Page 26
GENERAL INSTRUCTIONS
1. Invitation to Bidders
a. Deliver bid to:
Clerk of Circuit Court
Attention: Gary Stanford, Finance Director
Newman C. Brackin Bldg.
302 N. Wilson St., #203
Crestview, FL 32536
b. Bid opening will be:
January 8, 2014 @ 4:05 P.M.
Newman C. Brackin Bldg.
Conference & Training Room #305
Crestview, FL 32536
2. Bidding Documents - The Contract Documents for bidding may be examined and
obtained at the following office or they may be downloaded from our website at
www.co.okaloosa.fl.us (Departments, Purchasing, Vendor Registration & Opportunities); this
links you to the Florida Panhandle Purchasing Group website where our bid specifications
will now be posted.
Okaloosa County Purchasing Department
602-C North Pearl St.
Crestview FL 32536
850-689-5960
3. Preparation and Submission of Proposal
a. All Bids must be made on Proposal Forms, included herein, properly executed
and sealed in envelopes reflecting on the outside:
1) “Bid for Reroofing The Okaloosa County Tourist Development Welcome
Center"
2) “Bidder's Name and Phone Number"
3) “Bid Opening Date and Time”
Bids received by FAX will not be accepted.
b. The County reserves the right to reject any or all bids, waive informalities in any
Bid, and to make the award in the best interest of the County.
c. No changes in the amounts of Bids appearing on outside of Bids will be
considered. Only the amounts shown inside the envelope will be considered. All
changes, corrections and erasures MUST BE INITIALED by the person signing the
Bid.
4. Bid Price - The bid price shall include all equipment, labor, materials, permit(s), freight, taxes,
required insurance, Public Liability, Property Damage and Workers’ Compensation, etc., to
cover the finished work called for.
Page 27
5. Applicable Laws and Regulations - The bidders attention is directed to the fact that all
applicable state laws, county municipal ordinances, orders, rules and regulations of alll
authorities having jurisdiction over Project shall apply to the bid throughout, and they will be
deemed to be included in the contract the same as though they are written out in full
herein.
6. Permits - The contractor shall be responsible for obtaining any necessary permits and
licensing required by City and County offices.
7. Project Site - All bidders are required to visit the project site and become familiar with the
scope of work before submitting a bid.
8. Bid Information - Questions concerning bid requirements or specifications should be
directed to Richard Brannon at the Okaloosa County Purchasing Department, 602-C North
Pearl Street, Crestview, Florida 32536, at 850-689-5960 or 850-729-1400, Ext. 5960. Any
changes by the