Williams Pro Mar.200 semi-gloss latex (or
equal).
o Walls — 1 coat Sherwin Williams Pro Mar 200 primer and 2 coats Pro Mar 200 egg shell
(or equal).
o Ceilings ~ 1 coat Sherwin Williams Pro Mar 200 primer, 2 coats Pro Mar 200 Flat (or
equal).
o Steel Stairs and Rails — 2 coats Industrial Enamel
Specialties
e Seven each fire extinguishers and fire extinguisher cabinets are included in this budget.
e Doors signs are budgeted for code requirements as follows:
e 4each Toilet signs
® 5each Stair signs
e 2 each Elevator signs
« 1 each Elevator equipment room sign
* Standard commercial toilet accessories are include in the toilets ~- Toilet tissue dispenser,
paper towel dispenser, waste receptacles, framed mirror (18” x 36"), towel pins, towel bars
with shelf, shower curtain rods, and grab bars.
Aluminum canopy is included at the front poach as clear anodized aluminum. _
Metal building canopy will be included at the pedestrian door $102B. :
Furnishings
® Office cubicles are not included in this budget.
Special Construction
« A pre-engineered building will be 40-0 x 130-0 with a 28-0 average eave height. The building
will have a full second floor system including structural steel, bar joist, and metal decking.
« Roof is a single slope 1:12 standing seam metal roofing. Siding is stucco look concealed
fastener wail panel.
Insulation is R-19 at the roof, and R-13 insulation in the exterior walls.
Hoisting
e A2stop hydraulic elevaior is included in this proposal.
Mechanical
e Fire protection system is included as a wet pipe system. A fire pump is not included in this
proposal.
Piumbing is included to 5’-0” outside the building foot print.
HVAC | is quoted using heat pumps:
Eight each air handler and condenser units, two each PTAC units in the stairs, and one
each ductless split system in the elevator room.
Sheet meta! duct with insulation.
Grills, Registers, and diffusers are included.
Four each exterior wall louvers are included
= Two each exhaust fans and duct with backdraft dampers.
Stand-alone controls are included as shown.
Test & Balance is included.
Electrical
e Electrical is included per the drawings provided.
3
Lord & Son Construction Inc.
Okaloosa County Sheriff’s Office Addition, Shalimar, Florida
100% GMP Qualifications
e EMT is included for all branch conduits.
e All copper service conductors are included.
e Conduit and inner duct is provide for the data and communication systems only. The
communication and data systems are by others.
* Power connecis to system furniture is included. Power poles are to be furnished by the
owner's system furniture contractor.
« No Gulf Power charges are included.
Cost for the New Addition at the Sheriff's Office Shalimar $ 1,504,147.00
Sale Tax Savings 2% $ <30,083.00>
Total with Sales Tax Savings $ 1,474,064.00
Proposed Cost Savings:
Use MC Cable in lieu of EMT for electrical branch circuits - Deduct $ <3,100.00>
Delete PTAC’s in stair wells and add exhaust fans with louvers $ <3,860.00>
VkKaioosa VOUNLy Snerns Uirice aqaiuon
106% GMP
September 22, 2014
DV DESCRIPTION OF WORK Schematic Budget Total | 60% Budget Total 700% GMP TOTALS
‘Ta [GENERAL CONDITIONS ~~ a 08,637 [$ 106,487 |$ $3,642
1b__|GENERAL REQUIREMENTS mE 76,044
Te | TEMPORARY FENCE 5100} $
3 _|SITEWORK & STORM 5 25,634 27,160
3a _ [DEMOLITION 3500 8500
25 {UTILITIES 13 38,107 23.310
2c [DEWATER ELEVATOR PIT 13 19114 1$ 7.911
3d |FENCE Ts “TS 2.500
ROUGH CARPENTRY
CASEWORK
WINDOW SILLS (w/ Casework}
WATERPROOF ELEVATOR PIT
FRAMES, DOORS AND HARDWARE
ACCESS CONTROL
ALUMINUM WINDOWS & GLAZING
GYPSUM BOARD SYSTEM $
9a_ {ACOUSTICAL CEILING (W/Gyp Brd) $ 33,800 31,155 | $ :
9b [HARD TILE 4 10,878 13,810 8,500
9c__|CARPTET & RESILIENT E 27,500 27,600 16,677
Sd_|PAINT $ 25,975 25,975 47,350
EQUIPMENT
13 _|METAL BUILDING $ 230,868 234,525 233,314
13a_|METAL BUILDING ERECTION 71,250 73,313 83,000
{METAL BUILD UNLOAD 5733
ELEVATOR
FIRE PROTECTION
PLUMBING
HVAC
471,000
183,950
COMMUNICATIONS -
SUBTOTAL] $
4,191,219
1,431,343
4,362,771
“1191218 1,474,283 § 7404511
' BUILDERS RISK
ADD FOR BOND 14,082 $
OVERHEAD & PROFIT (5%)
BUILDING PERMIT (Allowance)
CONTRACT PRICE $ 1,269,512 $ 1,573,715 $ 1,504,147
CHANGE OWNER
Qo
ORDER ARCHITECT Q
CONTRACTOR a
FIELD ia
AIA DOCUMENT G701 (Modified) OTHER a
PROJECT: New Office Addition at the Okaloosa
County Sheriff's Office in Shalimar CHANGE ORDER NUMBER: One (1)
(name, address) 50 2" Street DATE: 2 July 2014
Shalimar, FL 32579
TO CONTRACTOR: ARCHITECT'S PROJECT NO: 14007
(name, address)
Lord & Son Construction, Inc. CONTRACT DATE: May 12, 2014
Post Office Box 1808
Fort Walton Beach, FL 32549 CONTRACT FOR: CM @ Risk Services
The Contract is changed as follows:
Additional work per Exhibit A (attached).
Not valid until signed by the Owner and Contractor.
The original (Contract Sum) was... $10,000.00
Net change by previously authorized Change Orders...............cecceeeeseeeees $0.00
The (Contract Sum) prior to this Change Order Was .............c.cec cee cee cesses ces cn eeecneee $10,000.00
The (Contract Sum)) will be (increased) by this Change Order in the amount of $306,730.00
The new (Contract Sum) including this Change Order will be .............ccccccecceeecee $316,730.00
The Contract Time will be changed by: N/A
The date of Substantial Completion as of the date of this Change Order therefore is: Per Contract
NOTE: This summary does not reflect changes in the Contract Sum, Contract Time or Guaranteed Maximum Price which have been authorized
by Construction Change Directive.
DAG Architects, Inc. Lord & Son Construction, Inc. Okaloosa County BOCC
Architect Contractor Owner
1223 Airport Road Post Office Box 1808 1804 Lewis Turner Blvd., Ste. 100
Destin, FL 32541 Fort Walton Beach, FL 32549 Fort Walton Beach, FL 32547
Address Address Address
By. By. By.
Charles W. Clary Ill, FAIA Leven D. Lord Il Kelly Windes
Architect President Chairman
Date: Date: Date:
AIA DOCUMENT G7014 - CHANGE ORDER * 1987 EDITION « AIA + 1987 * THE AMERICAN INSTITUTE OF ARCHITECTS
1755 NEW YORK AVE, NW., WASHINGTON, DC. 20006 G701-1987 (Modified)
Exhibit A to
New Office Addition at the Okaloosa County Sheriffs Office in Shalimar
. Kirby Building Systems $223,925.00
. Mowery ElevatorCo. — $35,750.00
. Jobe’s Dirt Works $8,500.00
Demolition of Existing Driveway
. Shalimar Fence Co. ____ $5,400.00
Relocation of Existing Fencing and
Additional Service Gates
. Choctaw Engineering Boundary Survey $1,950.00
. Supervisor/GCs (1 month) $7,640.00
. Insurance $6,462.00
. Bond $2,797.00
. Insurance Fee @ 5% $14,606.00
Total Change Order Amount: $306,730.00