August 18, 2015

Okaloosa County BOCC — August 18, 2015 — Electrical usage review and estimate

Electrical usage review and estimate in the August 18, 2015 Okaloosa County BOCC meeting materials. Preserved county-portal original with machine-generated OCR reading text.

FILED WITH

About this source

Preserved among the August 18, 2015 Okaloosa County Board of County Commissioners meeting materials (IQM2 meeting 1276). The date shown is the verified meeting context, not an independently established creation date for every attachment. The download catalog used June 15, 2015; the meeting date was corrected using the agenda/minutes heading and matching source filename.

Original publication
Electrical usage review and estimate
Date
August 18, 2015
Publisher
Okaloosa County Board of County Commissioners
Where to find it
2
Reference collection
Okaloosa County Board of County Commissioners (IQM2 public portal)

Source identity and meeting date checked. OCR text has not received independent human proofreading; consult the scan for names, numbers and uncertain characters.

HOW FAR THIS HAS BEEN CHECKED

File / copy authenticity
Preserved files carry a SHA-256 fingerprint fixed at ingest; whether those bytes match the original capture is not independently verified.
Transcription / extraction
Each reading-text file shows its recorded review status below.
Claim corroboration
Not independently verified
View reference catalogue / source ↗

Download this source

Electrical usage review and estimate — extracted reading text

Machine OCR from page images of the unchanged preserved PDF with source page boundaries retained. Not independently human proofread; consult the original scan for uncertain characters.

Text · 2.6 KB · 2

Download ↓

Electrical usage review and estimate — preserved PDF

Unchanged downloaded original; SHA-256 checked against the capture inventory.

PDF · 51.9 KB · 2

Download ↓

Reading text

Compare reading text with the preserved source. Line breaks and spacing are retained; long lines wrap to fit the screen. A file's role does not establish that its text has been checked.

Electrical usage review and estimate — extracted reading text

Machine-extracted OCR text · Review label: Known limitations

Atoacimest 2 M @ E Gene 1. Schmidt, P.E. CxA, LEED AP Mechanical/Plumbing 2 ) Todd A. Nicholson, P.E., LEED AP Electiical/Communications S C 8 CONSU T| NG GROU P,INC. Stuart C. Smith, P.E., S.1.. LEED AP~ Structural April 7, 2011 David Alsop Sam Marshall Architects ‘325 S. Palafox Street Pensacola, FL 32501 RE: NWFSC Community Services Complex Niceville, FL SCG Project No. 2006-226 Mr. Alsop, | have reviewed the electrical power demand for the Classroom/EOC portion of the Community Services Complex to determine an estimate of electrical power usage for the Classroom area versus the EOC area. | reviewed the scheduled connected load for both parts of the building - broken down into lighting, receptacles and mechanical equipment. These totals are as follows: Classroom Area a. Lighting load — 16.8 KW b. Receptacle load - 64.7 kW ¢.” Mechanical Equipment — 294.5 kW EQOC Area a. Lighting load — 37.6 KW b. Receptacle load — .280.9 kW ¢. Mechanical Equipment — 313.1 kW In order to determine an estimate of the power usage for each area, the hours of operation for each area must be considered. | estimated the lighting and receptacle loads for the Classroom area being used for 8 hrs/day. | estimated the mechanical equipment for the Classroom area being used for 12 hrs/day. The difference being the mechanical equipment cycling on and off during hours the Classroom area not being occupied. The lighting, receptacle and mechanical equipment loads for the EOC area are being used 24 hrs/day. By using these hours of operation the total kWhiday for each area can be estimated. These totals are as follows: Classroom Area a. Lighting load — 16.6 kW x 8 hrs/day = 132.8 kWh/day b. Receptacle load —64.7 kW x 8 hrs/day = 517.6 kWh/day - c. Mechanical Equipment — 294.5 kW x 12 hrs/day = 3,534 kWh/day Total = 4,184 kWh/day 40-S: PALAFOX PLACE, SUITE 360 PENSACOLA, FL-32502 P:850.438.0050 F:850.432.8631 www schmidtconsuliinggroup com ATACKMEUT 2 PAGE 2 OF 2 EQC Area a. Lighting load — 37.6 kW x 24 hrs/day = 902.4 kWh/day b. Receptacle ldad — 280.9 kW x 24 hrs/day = 6,741.6 kWWh/day ¢. Mechanical Equipment — 313.1 kW x 24 hrs/day = 7,514.4 kWh/day Total = 15,158.4 kWh/day Total estimate power usage/day — 4,184 kWhiday + 15,158.4 kWh/day = 19,342.4 kWh/day ' Classroom Area estimate usage/day — (4,184 kWh/day)/(19342.4 kWh/day) = 21.6% EOC Area estimate usage/day — (15,158.4 kWh/day)/(19342.4 kWh/day) = 78.4% Please let me know if you have any questions or need anything else. Respectfully yours, SCHMIDT CONSULTING GROUP, INC, fiholson, P.E., LEED AP Senior Vice President Electrical Engineer cc: File SCHMIDT CONSULTING GROUP, INC.

Download this text file with its original spacing ↓

Citation & reuse

Okaloosa County Board of County Commissioners. “Okaloosa County BOCC — August 18, 2015 — Electrical usage review and estimate.” August 18, 2015. Electrical usage review and estimate. Crypt of Echoes evidence ID LED-2026-85f9456d4de84fb8aefd8caf50064f47. http://127.0.0.1:58097/evidence/LED-2026-85f9456d4de84fb8aefd8caf50064f47. Accessed [date].

Catalogue citation: Okaloosa County Board of County Commissioners, Electrical usage review and estimate, meeting materials for August 18, 2015. https://okaloosacountyfl.iqm2.com/Citizens/FileOpen.aspx?Type=4&ID=9144&MeetingID=1276

Preserved county public-record source. Third-party attachments may retain their original rights.

Technical archive record ↓