READ ALONGSIDE THE SOURCE
Fort Walton Beach Ordinance — 1865 - Flood Plain Management — reading text
Part 5 of 9. These parts divide the reading text for browsing; they are not the source document's page numbers.
Machine-extracted text — fwb-31107-original.pdf
Machine-extracted OCR text · Review label: Machine produced / unreviewed
Compare this copy with the preserved source. Review labels describe the recorded status of this file; they do not guarantee that the text is error-free. Spacing and line breaks are retained, with long lines wrapped to fit the screen.
hazard
areas, alteration of sand dunes and mangrove stands shall be permitted only if such
alteration is approved by the Florida Department of Environmental Protection and only if
the engineering analysis required by section 3. 05. 05( C) of this code demonstrates that the
proposed alteration will not increase the potential for flood damage. Construction or
restoration of dunes under or around elevated buildings and structures shall comply with
section 3. 05. 14( H) of this code.
3. 05. 12 Flood Resistant Development —Manufactured Homes
A. General. All manufactured homes installed in flood hazard areas shall be installed by
an installer that is licensed pursuant to section 320. 8249, F. S., and shall comply with the
requirements of Chapter 15C- I, P.A. C. and the requirements of this section.
B. Foundations. All new manufactured homes and replacement manufactured homes
installed in flood hazard areas shall be installed on permanent, reinforced foundations
that:
1. In flood hazards areas ( Zone A) other than coastal high hazard areas, are designed
in accordance the foundation requirements of the Florida Building Code,
Residential Section R322. 2 and this section.
2. In coastal high hazard areas ( Zone V), are designed in accordance with the
foundation requirements of the Florida Building Code, Residential Section
R322.3 and this section.
C. Anchoring. All new manufactured homes and replacement manufactured homes shall
be installed using methods and practices which minimize flood damage and shall be
securely anchored to an adequately anchored foundation system to resist flotation,
collapse or lateral movement. Methods of anchoring include, but are not limited to, use of
over -the -top or frame ties to ground anchors. This anchoring requirement is in addition to
applicable state and local anchoring requirements for wind resistance.
D. Elevation. Manufactured homes that are placed, replaced, or substantially improved
shall comply with section 3. 05. 12 ( E) or 3. 05. 12 ( F) of this code, as applicable.
E. General elevation requirement. Unless subject to the requirements of section 3. 05. 12
F) of this code, all manufactured homes that are placed, replaced, or substantially
improved on sites located: ( a) outside of a manufactured home park or subdivision; ( b) in
a new manufactured home park or subdivision; ( c) in an expansion to an existing
manufactured home park or subdivision; or ( d) in an existing manufactured home park or
17
subdivision upon which a manufactured home has incurred " substantial damage" as the
result of a flood, shall be elevated such that the bottom of the frame is at or above the
elevation required, as applicable to the flood hazard area, in the Florida Building Code,
Residential Section R322. 2 ( Zone A) or Section R322.3 ( Zone V).
F. Elevation requirement for certain existing manufactured home parks and
subdivisions. Manufactured homes that are not subject to section 3. 05. 12 ( E) of this
code, including manufactured homes that are placed, replaced, or substantially improved
on sites located in an existing manufactured home park or subdivision, unless on a site
where substantial damage as result of flooding has occurred, shall be elevated such that
either the:
1. Bottom of the frame of the manufactured home is at or above the elevation
required, as applicable to the flood hazard area, in the Florida Building Code,
Residential Section R322.2 ( Zone A) or Section R322.3 ( Zone V); or
2. Bottom of the frame is supported by reinforced piers or other foundation elements
of at least equivalent strength that are not less than 36 inches in height above
grade.
G. Enclosures. Fully enclosed areas below elevated manufactured homes shall comply
with the requirements of the Florida Building Code, Residential Section R322 for such
enclosed areas, as applicable to the flood hazard area.
H. Utility equipment. Utility equipment that serves manufactured homes, including
electric, heating, ventilation, plumbing, and air conditioning equipment and other service
facilities, shall comply with the requirements of the Florida Building Code, Residential
Section R322, as applicable to the flood hazard area.
3. 05. 13 Flood Resistant Development —Recreational Vehicles and Park Trailers
A. Temporary placement. Recreational vehicles and park trailers placed temporarily in
flood hazard areas shall:
1. Be on the site for fewer than 180 consecutive days; or
2. Be fully licensed and ready for highway use, which means the recreational vehicle
or park model is on wheels or jacking system, is attached to the site only by
quick -disconnect type utilities and security devices, and has no permanent
attachments such as additions, rooms, stairs, decks and porches.
B. Permanent placement. Recreational vehicles and park trailers that do not meet the
limitations in section 3. 05. 13 of this code for temporary placement shall meet the
requirements of section 3. 05. 12 of this code for manufactured homes.
3. 05. 14 Flood Resistant Development —Tanks
A. Underground tanks. Underground tanks in flood hazard areas shall be anchored to
prevent flotation, collapse or lateral movement resulting from hydrodynamic and
18
hydrostatic loads during conditions of the design flood, including the effects of buoyancy
assuming the tank is empty.
B. Above -ground tanks, not elevated. Above -ground tanks that do not meet the
elevation requirements of section 3. 05. 14 ( C) of this code shall:
1. Be permitted in flood hazard areas ( Zone A) other than coastal high hazard areas,
provided the tanks are anchored or otherwise designed and constructed to prevent
flotation, collapse or lateral movement resulting from hydrodynamic and
hydrostatic loads during conditions of the design flood, including the effects of
buoyancy assuming the tank is empty and the effects of flood -borne debris.
2. Not be permitted in coastal high hazard areas ( Zone V).
C. Above -ground tanks, elevated. Above -ground tanks in flood hazard areas shall be
attached to and elevated to or above the design flood elevation on a supporting structure
that is designed to prevent flotation, collapse or lateral movement during conditions of
the design flood. Tank -supporting structures shall meet the foundation requirements of
the applicable flood hazard area.
D. Tank inlets and vents. Tank inlets, fill openings, outlets and vents shall be
1. At or above the design flood elevation or fitted with covers designed to prevent
the inflow of floodwater or outflow of the contents of the tanks during conditions
of the design flood; and
2. Anchored to prevent lateral movement resulting from hydrodynamic and
hydrostatic loads, including the effects of buoyancy, during conditions- of the
design flood.
3.05. 15 Flood Resistant Development— Other Development
A. General requirements for other development. All development, including man-
made changes to improved or unimproved real estate for which specific provisions are
not specified in this section or the Florida Building Code, shall:
1. Be located and constructed to minimize flood damage;
2. Meet the limitations of section 3. 05. 1 1 ( D) of this code if located in a regulated
floodway;
3. Be anchored to prevent flotation, collapse or lateral movement resulting from
hydrostatic loads, including the effects of buoyancy, during conditions of the
design flood;
4. Be constructed of flood damage- resistant materials; and
5. Have mechanical, plumbing, and electrical systems above the design flood
elevation, except that minimum electric service required to address life safety and
electric code requirements is permitted below the design flood elevation provided
it conforms to the provisions of the electrical part of building code for wet
locations.
19
B. Fences in regulated floodways. Fences in regulated floodways that have the
potential to block the passage of floodwaters, such as stockade fences and wire mesh
fences, shall meet the limitations of section 3. 05. 11 ( D) of this code.
C. Retaining walls, sidewalks and driveways in regulated floodways. Retaining walls
and sidewalks and driveways that involve the placement of fill in regulated floodways
shall meet the limitations of section 3. 05. 11 ( D) of this code.
D. Roads and watercourse crossings in regulated floodways. Roads and watercourse
crossings, including roads, bridges, culverts, low -water crossings and similar means for
vehicles or pedestrians to travel from one side of a watercourse to the other side, that
encroach into regulated floodways shall meet the limitations of section 3. 05. 11 ( D) of this
code. Alteration of a watercourse that is part of a road or watercourse crossing shall meet
the requirements of section 3. 05.05 ( C) of this code.
E. Concrete slabs used as parking pads, enclosure floors, landings, decks, walkways,
patios and similar nonstructural uses in coastal high hazard areas ( Zone V). In
coastal high hazard areas, concrete slabs used as parking pads, enclosure floors, landings,
decks, walkways, patios and similar nonstructural uses are permitted beneath or adjacent
to buildings and structures provided the concrete slabs are designed and constructed to
be:
1. Structurally independent of the foundation system of the building or structure;
2. Frangible and not reinforced, so as to minimize debris during flooding that is
capable of causing significant damage to any structure; and
3. Have a maximum slab thickness of not more than four (4) inches.
F. Decks and patios in coastal high hazard areas ( Zone V). In addition to the
requirements of the Florida Building Code, in coastal high hazard areas decks and patios
shall be located, designed, and constructed in compliance with the following:
1. A deck that is structurally attached to a building or structure shall have the bottom
of the lowest horizontal structural member at or above the design flood elevation
and any supporting members that extend below the design flood elevation shall
comply with the foundation requirements that apply to the building or structure,
which shall be designed to accommodate any increased loads resulting from the
attached deck.
2. A deck or patio that is located below the design flood elevation shall be
structurally independent from buildings or structures and their foundation
systems, and shall be designed and constructed either to remain intact and in place
during design flood conditions or to break apart into small pieces to minimize
debris during flooding that is capable of causing structural damage to the building
or structure or to adjacent buildings and structures.
3. A deck or patio that has a vertical thickness of more than twelve ( 12) inches or
that is constructed with more than the minimum amount of fill necessary for site
20
drainage shall not be approved unless an analysis prepared by a qualified
registered design professional demonstrates no harmful diversion of floodwaters
or wave runup and wave reflection that would increase damage to the building or
structure or to adjacent