Compare this copy with the preserved source. Review labels describe the recorded status of this file; they do not guarantee that the text is error-free. Spacing and line breaks are retained, with long lines wrapped to fit the screen.
Further clarifications regarding the scope of this certificate and the applicability of the management
system requirements may be obtained by consulting the organization.
Certificate No: US003759-1
Issue Date: 9 March 2011
Revision Date: 11 April 2012
SRA [ Mae ? wala
«WV, : ; .
For Burd4u Veritas Certification North America, Inc.
390 Benmar Drive, Houston, Texas, USA
www.us.bureauveritas.com /bve
ACCREDITED
Certification
Awarded To
INSITUFORM TECHN OLOGIES, LLC.
HQ — 17988 EDISON AVE, CHESTERFIELD, MO, 63005 USA
APPENDIX TO CERTIFICATE NUMBER: US003759-1
Bureau Veritas Certification North America, Inc. certifies that the management system of the above
organization (including the locations listed below) has been audited and found to be in accordance with
the requirements of the management system standards detailed below
STANDARDS
ISO 9001:2008
CERTIFIED LOCATIONS
Site 2 (R&D Quality/Part of HQ Campus): Site 3 (Manufacturing): 160 Corporate Drive, Batesville, MS 38606
17999 Edison Ave, Chesterfield, MO 63005 Site Scope: Manufacturing
Site Scope: Design & Development, Applications Engineering,
validation/Testing, video
Site 4 (Wetout): 7605 18th Street, Edmonton, Alberta T6P 1N9, Site 5 (Wetout): 2130 Stout Field West Drive, Indianapolis, IN 46241
Canada Site Scope: Manufacturing
Site scope: Manufacturing
Site 6 (Wetout): 912 Stanton Road, Olyphant, PA 18447 Site 7 (Wetout): 3061 Dublin Circle, Bessemer, AL 35022
Site Scope: Manufacturing Site Scope: Manufacturing
Site 8 (Wetout): 468 Cypress Road, Ocala, FL 34472 Site 9 (Wetout): 6526 Bluebonnet Parkway, McGregor, TX 76657
Site Scope: Manufacturing Site Scope: Manufacturing
Site 10 (Wetout): 2255 West 85 North Cedar City, UT 84721 Site 11 (Wetout): 91-255 Kalaeloa Boulevard, Kapolei, HI 96707
Site Scope: Manufacturing Site Scope: Manufacturing
Site 12 (Installation East): 1860 Freeman Parkway, Mableton, Site 13 (Installation Central): 580 Goddard Ave, Chesterfield, MO
GA 30126 63005
Site Scope: Preparation and Installation Site Scope: Preparation and Installation
Site 14 (Installation West): 9654 Titan Court, Littleton, CO Site 15 (Installation Canada): 7605 18 Street Northwest, Edmonton,
80125 Alberta T6P 1N9, Canada
Site Scope: Preparation and Installation Site Scope: Preparation and Installation
Subject to the continued satisfactory operation of the Organization’s Management System,
this appendix will remain valid until: 8 March 2014
Issue Date: 9 March 2011
Revision Date: 11 April 2012
For Bute) Veritas Certification North America, Inc.
390 Benmar Drive, Houston, Texas, USA
Wwww.us. bureauveritas.com/bvc
ACCREDITED
. Independent Test Results
Product tested:
Cured-in-Place Pipe Insituform® Process
Test:
Design Life
Conducted hy:
Trenchless T Center at Louisi
INNOVATIVE METHODS OF TESTING the long-term Toon Unversity tuned by US Army Corps of
structural behavior of Cured-in-Place Pipe (CIPP) Engineers
demonstrates that the Insituform product design —
life exceeds 50 years and that ASTM F-1216 Report Date:
. ‘ . August 1994
design recommendations for physical properties
are conservative for the Insituform product.
The research was conducted by the Trenchless
Technology Center (TTC) at Louisiana Tech University
and funded by the U.S. Army Corps of Engineers.
The purpose was to provide, for the first time, an
independent assessment of manufacturer’s claims | The research included both experimental and
regarding long-term buckling behavior of their analytical studies related to the application of
pipeline rehabilitation products. CIPP and Fold-and-Formed Pipe (FFP) technologies
In partially deteriorated, gravity pipeline applications
Research conducted by the where onding dd not exist between the plastic
Trenchless Technology Center Five manufacturers participated in the test
program. Seven different products, including
at Lo uIs tana Tech U; TIVE. Ss ity six CIPP products and one FFP product, were
evaluated in approximately 200 tests. Insituform
; ?
conjir. ms Insituform S products that were tested included Insituform?
° . . Standard, which is a widely used polyester resin
50-year design life. Insitupipe® material, and Insituform® Enhanced,
which contains an additive to the polyester resin
The expected design [lfe and Jong-term behavior —_to increase the flexural properties of the finished
of trenchless pipeline rehabilitation products is Insituform product. —
important to owners and engineers in evaluating The plastic pipes were encasad in steel pipes,
. the various systems available in the marketplace, with hydrostatic pressure applied between the
especially since none of these systems have been =. pipes. To measure long-term performance,
in actual service for the design lives claimed. each test remained under constant pressures
This becomes even more critical considering for up to 10,000 hours or until failure, whichever
the recent growth of the trenchless pipeline occurred first. The test results were plotted and
rehabiltation industry and that many products extrapolated beyond the test period to estimate
have less than five years of experience. behavior up to 50 years.
Standardized material tests (flexure, tensile
and pipe stiffness tests) were also conducted
to characterize the fundamental properties
of the product materials.
Figure 1
Figure 2
PUTTING CLAIMS TO THE TEST
Overview of Test System and Procedures
The installation of all products used in the test was
performed by the manufacturers on the Louisiana
Tech University campus under close monitoring by
TT¢ personnel. Forty specimens each of Insituform
x Standard and Insituform
Enhanced were tested.
Each test specimen was
installed to fit snugly inside
a 1.83 m (6 ft.) long, 3065 mm
(42 in.) internal diameter,
schedule 40 steel casing
pipe. Each casing pipe was
fitted with short, bolted
pipe segments (clamshells)
at each end. {See Figure 1).
" Preparing the specimens for testing involved trim-
ming the ends flush with the clamshells, removing
the clamshelts, and cleaning the ends of the speci-
mens. This resulted in the plastic
pipe extending beyond the ends
of the steel casing pipes. The
specimens were then fitted with
end seals applied externally, span-
ning the casing pipe and plastic
pipe. (See Figure 2). The end
seals contained the water at the
prescribed pressure, which was
Table 1
Material Characterization Tesis (Short. term)
supplied between the plastic and casing pipes from
a pressurized water distribution system.
At least three specimens of each product were
used for short-term buckling tests to determine
the upper pressure jimit for the long-term tests.
A regulator was used to raise the pressure on
the specimen, and the rate of load application
was kept constant until failure occurred.
For the long-term tests, each specimen was
pressurized at a controlled rate of 10 psi/minute
(69 kPa/minute) until a selected pressure was
reached, A minimum of five pressure ievels were
selected for each product to cause the specimens to
fail at various times over a 10,000-hour test period.
Specimens were monitored at least once a day
for evidence of buckling. Failures that occurred
during normal work hours were monitored
Manually, After normal work hours, failures
were detected electronically.
terial Characterizati ti
Numerous tests, including flexural modulus, flexural
strength and tensile strength, were conducted on
each product according to ASTM standards. On each
of these tests, the results found that both Insituform
products far surpassed the design values.
(See Table 1).
SITUFORK -
w MANUFACTURER'S “THC TEST
: Flexural Strength .:
ov Fram TG Technet Report 4302, Tab 42
PRODUCT. =... > VTEST =°—siws:s.. DESIGNYALUE == RESULTS
ae ars METHOD _psl (MPa) nsl (MPa)
~~ Flexural Modulus. Standard. = -D790. «= 800,000.” 448,630.”
(2070) 2 (8080)
Enhanced “D790... 400,000. *.”. 538,620 «
Standard DTD
SHORT-TERM TEST RESULTS GREEP FACTOR
Short-ferm buckling tests demonstrate that Creep factor reflects the reduction in buckling resistance of a plastic pipe over
Insituform design is conservative in terms of time, typically 50 years. The creep factor, C,, Is the ratio of Experimental E, to
both the enhancement factor, K, and the predicted the measured flexural modulus reported in Table 1 and represents the retention
buckling pressures using the following ASTM of buckling resistance at 50 years {i.e., E, = C, E). A value of C, greater than
F-1216 design model: the manufacturer's recommended value Is desirable. As shown in Table 2,
ihe reported creep factor confirms the conservative nature of the 50% creep
ps 2KE, e 1 ° C (1) reduction factor applied to flexural modulus in the Insituform product design.
(FA) * (DR-T)" N rebte 2
able
where, P = Buckling pressure, psi (MPa) Creep Factor
K = Enhancement factor I ene
E, = Long-term (time-corrected)
modulus of elasticity, ps! (MPa)
11 = Polsson’s ratio
DR= Dimension ratio (outside diameter
divided by thickness)
C = Ovality factor = 1 (for test program)
N = Safety factor = 7 (for analysis
of test data) LONG-TERM TEST RESULTS
The enhancement factor, K, is a measure of the Regression analysis was used to extrapolate long-term buckling pressures
restraining action of the host pipe that encases beyond the 10,000-hour test period to 50 years. (See Figure 3, next page).
the Insituform product and greatly increases
the allowable external buckling pressure. A Flexural Modu
conservative enhancement factor of 7 Is Test results supported the flexural modulus reduced to account for
typically recommended for design. The tests long-term effects, F,, used in the Insituform product design, by comparing
measured the average enhancement factor, it to the experimentally derived apparent long-term flexural modulus for a
K, of the Insituform Standard at 9.8 and the 50-year design lifé. The tested value greatly exceeded the conservative
Insituform Enhanced product at 10.5. value used in the Insituform product design. (See Table 3).
Table 3
Flexural Modulus (Long-term)
“TTC Bmptimental E, Manutecturer
. 0 2 pst (MPayo Recommended Design
Os psi(MPa)
- Insituform Standard: “269,990... 450,000,
FBO) 1080)
Insituform Enhanced - 393,965 200,000.
From TTC Tehieal Report #202, Tale 4:8 a in as Boe es
LONG-TERM BUCKLING BEHAVIOR
It is important that the design procedures used
for a rehabilitation product accurately predict .
the long-term structural behavior of the product.
The TIC data analysis compared the Jong-term
buckling test data to that predicted by Equation 1.
This comparison indicated that Equation 1 conser-
vatively predicts long-term hydrostatic buckling
behavior of both insituform products.
Regression ia
© TIMETO FAILURE, t (hour)
(Report #802, Tale 6
Figure 3. Long-term Test and Regression
flasulis for insituform Enhanced Product.
AB1248
7/01
© 2001 tnsituform Technotogles, Inc.
50 - PLUS YEARS DESIGN LIFE
One of the primary goals of the TTC test program
- was to evaluate the design lives of various reha-
bilitation products. This was accomplished by
comparing the 50-year extrapolated test pressure
to the design 50-year buckling pressure calculated
using Equation 1 with manufacturer's recommended
design values for E,. An Insituform design life in
excess of 50 years was contirmed.
WITHSTANDING THE TESTS OF TIME
The most rigorous, innovative and Independent
tests ever conducted on pipeline rehabilitation
products clearly demonstrates that service life
beyond 50 years can be expected with properly
designed and Installed Insituform products.
A copy of “Long-Term Structural Behavior of
Pipeline Rehabilitation Systems” (TTC Technical
Report #302) may be obtained by writing:
Trenchless Technology Center
Louisiana Tech University
P.O. Box 10348
Ruston, Louisiana 71272
or by calling (318) 257-4072.
© Insituform
Technologies, Inc.
Worldwide Pipeline Rehabilitation
702 Spirit 40 Park Drive
Chesterfield, MO 63005
Toll Free: 800-234-2992
Phone: 636-530-8000