J Wet Locations 0 All wet location receptacle outlets and inlet devices, including those on hardwired remote V- distribution boxes, shall be of the grounding type provided with a wet location cover and p U1 installed in accordance with Section 210 -7 " Receptacles and Cord Connections" of the NEC. L All receptacles located in a wet location shall be not less than 24 inches ( 610 mm) from the ground. Receptacles on off -road vehicles shall be a minimum of 30 inches ( 762 mm) from the a CO ground. The face of any wet location receptacle shall be installed in a plane from vertical to not more than 45 degrees off vertical. No receptacle shall be installed in a face up position. U. Dry Locations a All receptacles located in a dry location shall be of the grounding type. Receptacles shall be Y not less than 30 inches ( 762 mm) above the interior floor height. All receptacles shall be marked with the type of line voltage ( 120 -volts or 240 -volts) and the current rating in amps. If the receptacles are direct current, or other than single phase, they shall be so marked. R w Listing E All receptacles and electrical inlet devices shall be listed to UL 498, Standard for Safety Attachment Plugs and Receptacles, or other appropriate performance standards. Receptacles a used for direct current voltages shall be rated for the appropriate service. Electrical System Testing The wiring and associated equipment shall be tested by the apparatus manufacturer or the installer of the line voltage system. The wiring and permanently connected devices and equipment shall be subjected to a dielectric voltage withstand test of 900 -volts for one ( 1) minute. The test shall be conducted between live parts and the neutral conductor, and between live parts and the vehicle frame PagePage 7272 ofof 9393 14,2. b with any switches in the circuit(s) closed. This test shall be conducted after all body work nas been completed. Electrical polarity verification shall be made of all permanently wired equipment and receptacles to determine that connections have been properly made. Operational Test per Current NFPA 1901 Standards The apparatus manufacturer shall perform the following operation test and ensure that the power source and any devices that are attached to the line voltage electrical system are properly connected and in working order. The test shall be witnessed and the results certified by an independent third -party certification organization. The prime mover shall be started from a cold start condition and the line voltage electrical system loaded to 100 percent of the nameplate rating. v The power source shall be operated at 100 percent of its nameplate voltage for a minimum of two (2) hours unless the system meets category certification as defined in the current NFPA 1901 standard. J Where the line voltage power is derived from the vehicle' s low voltage system, the minimum M continuous electrical load as defined in the current NFPA 1901 standard shall be applied to the r O low voltage electrical system during the operational test. Tr a Meets Exceeds Comments: 257. GENERATOR The apparatus shall be equipped with a complete AC ( alternating current) electrical power a system. The generator shall be a 10, 000 watt hydraulic driven unit. 00M N The generator shall be driven by a transmission power take off unit, through a hydraulic pump and motor. The hydraulic engagement supply shall be operational only after the chassis parking brake is applied. c tL An electric /hydraulic valve shall supply hydraulic fluid to the clutch engagement unit provided NU a) a on the chassis PTO drive. U Generator Instruments and Controls 3 To properly monitor the generator performance a digital meter panel shall be furnished and mounted near the circuit breaker panel in close proximity to the driver' s side pump panel. Jo Meets Exceeds Comments: r_ E 258. GENERATOR LOCATION ZI The generator shall be mounted in the cargo area at the front of the body in the dunnage area. The flooring in this area shall be either reinforced or constructed, in such a manner, that it shall handle the additional weight of the generator. Meets Exceeds Comments: 259. GENERATOR START A switch shall be located on the cab instrument panel to engage the generator and a second switch shall be located on the driver's side pump panel. Page 73 of 93 Meets Exceeds Comments: 260. CIRCUIT BREAKER PANEL The circuit breaker panel shall be located in a forward compartment on the left side of vehicle. Specifics regarding construction, mounting, and operation shall be contained in the proposal. Meets Exceeds Comments: 261. 120 VOLT LIGHTING, TIP OF LADDER There shall be Two ( 2) non -telescoping, permanent swivel mount flood lights provided at the tip of the ladder. The light(s) shall be located on the driver and passenger side. Light( s) shall Y U be 120 volts. Light( s) shall be switched at the light head, pump panel, and turntable. A 120 L volt receptacle shall also be available at the ladder tip. d Meets Exceeds Comments: o 262. ELECTRIC CORD REEL 0 Furnished with the 120 volt AC electrical system shall be a cord reel. The reel shall be a provided with a 12 -volt electric rewind switch, that is guarded to prevent accidental operation and labeled for its intended use. The switch shall be protected with a fuse and installed at a height not to exceed 72 inches above the operators standing position. a The reel shall be capable holding 12/ 3 600 volt cable or 10/ 3 600 volt cable. co M N The reel shall include the following features: Heavy -duty construction for durability All stainless steel hardware Rolled disc edges Live slip ring design Includes the gang box attached to end of electrical cable Universal frame with four motor locations Meets NFPA requirements for reel overage of 10% The exterior finish of the reel( s) shall be painted job color matching the body exterior.. A captive roller assembly to be provided to aid in the payout and loading of the reel. A ball stop shall be provided to prevent the cord from being wound on the reel. A label shall be provided in a readily visible location adjacent to the reel. The label shall indicate current rating, current type, phase, voltage and total cable length. A total of one ( 1) cord reel shall be provided in the dunage area, or other location agreed upon by customer, with accompanying an accompanying roller guide assembly. The cord reel should be configured with three ( 3) conductors. Meets Exceeds Comments: Page 74 of 93 14.2. b 263. REEL WARRANTY The electric reel shall come with a minimum five ( 5) year warranty provided by the reel manufacturer. Meets Exceeds Comments: 264. CORD Provided for electric distribution shall be one ( 1) length installed on the reel of 200 feet of yellow 10/ 3 electrical cord, weather resistant 105 degree C to - 50 degree C, 600 volt jacketed SOOW cord. A Hubbell 1- 5 -20, 20 amp, 120 volt, twist lock connector body shall be installed on the end of the cord. Meets Exceeds Comments: a 265. 20 AMP RECEPTACLE Wired to the power supply shall be four (4) receptacles that are a 120 volt 20 amp three wire M twist -lock NEMA L5 -20 type with weather resisting cover located one each side body fender o panels and two at rear of apparatus. a U. Meets Exceeds Comments:

Download this text file with its original spacing ↓