a Meets Exceeds Comments: MN00 r t6 235. FOAM LEVEL GAUGE U_ An electronic foam level gauge shall be provided on the operator's panel that registers foam level by means of five colored LED lights. The lights shall be durable, ultra -bright five LED a design viewable through 180 degrees. The foam level indicators shall be as follows: 3 100% = Green L d 75% = Yellow 50% = Yellow J w c 25% = Yellow E Refill = Red M a The light shall flash when the level drops below the given level indicator to provide an eighth of a tank indication. To further alert the pump operator, the lights shall flash sequentially when the foam tank is empty. The level measurement shall be based on the sensing of head pressure of the fluid in the tank. The display shall be constructed of a solid plastic material with a chrome plated die cast bezel to reduce vibrations that can cause broken wires and loose electronic components. The encapsulated design shall provide complete protection from foam and environmental elements. An industrial pressure transducer shall be mounted to the outside of the tank. The Page 66 of 93 display shall be able to be calibrated in the field and shall measure head pressure to accurately show the tank level. Meets Exceeds Comments: 236. SIDE CONTROL PUMP OPERATOR' S /PUMP PANEL LIGHTING Illumination shall be provided for controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus and the equipment provided on it. Proposals shall provide details of on the type, location, construction, and operation of pump panel lighting. Meets Exceeds Comments: Y V L 7 237. ELECTRICAL HARNESSING INSTALLATION d Proposals shall provide details regarding the installation, routing, construction, a labeling, and protection of the apparatus electrical wiring harness. M J Meets Exceeds Comments: M r O r a 238. BATTERY CABLE INSTALLATION U- Proposals shall include details regarding the installation, routing, construction, M labeling, and protection of the vehicle' s battery cables. 3 a Meets Exceeds Comments: 00M N n 239. STEP LIGHTS Two ( 2) step lights shall be provided on the aerial body. The step lights shall be actuated by the aerial master switch in the cab. All other steps on the apparatus shall be illuminated per the current edition of NFPA 1901 Meets Exceeds Comments: 240. REAR FMVSS LIGHTING AND DOT /MARKER LIGHTING Proposals shall provide details of intended lighting to be used. Meets Exceeds Comments: 241. PUMP COMPARTMENT LIGHT A pump compartment light shall be provided inside the right side pump enclosure and accessible through a door on the pump panel. A weep hole shall be provided in each light lens, preventing moisture retention. Meets Exceeds Comments: Page 67 of 93 242. PERIMETER SCENE LIGHTS, CAB There shall be a minimum 4. 00 ", LED, grommet mount weatherproof light provided for each cab door. Lighting shall be designed to provide illumination on areas under the driver, officer, and crew cab riding area exits, which shall be activated automatically when the exit doors are opened, by the door jam switch and by the same means as the body perimeter lights. The lighting shall be capable of providing illumination at a minimum level of two ( 2) foot - candles on ground areas within 30. 00" of the edge of the apparatus in areas which personnel climb in or out of the apparatus or descend from the apparatus to the ground level. Meets Exceeds Comments: 243. PERIMETER SCENE LIGHTS, BODY There shall be a total of eight (8) LED lights provided on the apparatus body. Each light shall L consist of a minimum 4. 00" weatherproof LED light, rubber mount, and pigtail kit. d o The lights shall be mounted in the following locations: J Two (2) lights shall be provided under the rear step area. 0 One ( 1) light shall be provided directly fore and aft of the rear tire area on each side a U- One ( 1) light shall be provided each side under the pump panel running boards. The lighting shall be capable of providing illumination at a minimum level of two ( 2) foot - 3 candles on ground areas within 30. 00" of the edge of the apparatus in areas designed for a personnel to climb onto the apparatus or descend from the apparatus to the ground level. 00 MN r The lights shall be activated by a parking brake control and driver side overhead switch panel and officer side overhead switch panel. U- Meets Exceeds Comments: CD CL W 244. 12 VOLT LIGHTING At minimum, there shall be 12 -volt scene lighting on each side of the cab, two ( 2) brow scene lights on front of cab, two (2) Collins lights at the tip and at the base of the aerial ladder, and two (2) scene lights at the rear of the vehicle. Proposals shall provide details regarding the o style, type, brand, construction, location, number, and operation of all proposed 12 -volt J lighting. E s Meets Exceeds Comments: 245. PORTABLE HAND LIGHTS, PROVIDED BY MANUFACTURER Four (4) portable hand lights mounted in brackets fastened to the apparatus shall be provided by the vehicle manufacturer. Lights and mounting locations to be determined by customerl. Meets Exceeds Comments: Page 68 of 93 246. SPOTLIGHTS ` There shall be a manually operated, cab mounted spotlight available for the driver and one for the officer. Meets Exceeds Comments: 247. REAR VISION SYSTEM There shall be one ( 1) color rear view camera with microphone located at the rear of the apparatus as close to center as possible and activated when the vehicle is in reverse. Images shall be displayed in the cab on the display provided. An amplified speaker with volume control permitting audio from the active camera shall also be provided in the cab connected to an intercom module with volume control within reach of the driver. Meets Exceeds Comments: d 248. GUARD, REAR BODY CAMERA J An aluminum treadplate guard shall be fastened over the rear body camera to protect from M damage and theft. 0 Meets Exceeds Comments: a 249. AIR HORN SYSTEM Two ( 2) air horns shall be provided and located, in the front bumper, recessed out board of a co frame. The horn system shall be piped to the air brake system wet tank. A pressure N M protection valve shall be installed in -line to prevent loss of air in the air brake system. Meets Exceeds Comments: U_ 250. AIR HORN

Download this text file with its original spacing ↓