READ ALONGSIDE THE SOURCE

Fort Walton Beach Council agenda — 04-26-11 regular — reading text

Part 28 of 65. These parts divide the reading text for browsing; they are not the source document's page numbers.

Machine-extracted text — fwb-26904-original.pdf

Machine-extracted OCR text · Review label: Machine produced / unreviewed

Compare this copy with the preserved source. Review labels describe the recorded status of this file; they do not guarantee that the text is error-free. Spacing and line breaks are retained, with long lines wrapped to fit the screen.

eliminate the requirement of transporting the vehicle outside the fire department jurisdiction. A copy of the technicians EVT certificates listing the certified classifications is included as required by the specifications in the Certification section of the proposal. Authority of Specifications The buyer' s specifications, together with any other documents required herein, will be included in the final contract. A copy of the Sunbelt Fire, Inc. standard contract is included for your review. All design, operational and material features must fully comply with the State and Federal Motor Vehicle Safety Standards ( FMVSS) as stated in Public Law Number 90 -563. Manufacturer History A written review of the company, in chronological order, detailing the background of the manufacturer will be provided as part of the bid proposal. 3 31onil aappe-1 - £ 60- 6 d=121 paeMV : 8£ Z0 aald } loqung woi} lesodo.ad :; uaWyoe; ;y SunbeltFire City of Fort Walton Beach Proposal for 78' Aerial Quint C<=*) Options The following options are offered per the advertised specification and have not been included in the bid price. Any addition of trays, shelves, or toolboards is subject to engineering approval. Option No. 1 A floor mounted roll -out tray is being provided as an option. The roll -out tray shall be constructed of 3/ 16" (. 187 ") smooth aluminum plate with a sanded finish and welded corners for increased strength and rigidity. The tray shall be sized in width and depth as applicable. For greater tray accessibility, the drawer slides shall feature one hundred percent extension. The tray shall utilize a pneumatic shock to secure the tray in the open or closed position. The tray shall have a total capacity of 500 lbs. Option Price: $ 616. 00 Option No. 2 An adjustable roll -out tray is being provided as an option. The roll -out tray shall be constructed of 3/ 16" (. 187) smooth aluminum with welded corners for strength and rigidity. The tray shall be sized in width and depth as applicable. For greater tray accessibility, the drawer slides shall feature one hundred percent extension. The tray shall utilize a gas shock to hold the tray in an open or closed position. The tray shall have a total capacity of 500 lbs. Option Price: $ 970. 00 Option No. 3 An aluminum adjustable shelf is being provided as an option. The shelf shall be constructed of 3/ 16" (. 187 ") smooth aluminum plate. The shelf shall have a minimum 2" front lip to accommodate optional plastic interlocking compartment tile systems. For additional strength and reinforcement of the shelf a Super Z break shall be provided. The adjustable shelf shall be capable of holding 250 lb. The shelf shall be sized, width and depth, to match the size and location in the compartment. Option Price: $ 313. 00 0 3l3n.il aappe-I - £ 40- 44 dia Paenny: SEW eq j Ilaqung woaj lesodoad : ;uauayoe; iv SunbeftFire City of Fort Walton Beach Proposal for 78' Aerial Quint D> C<= Option No. 4 A permanent mounted aluminum shelf is being provided as an option. The shelf shall be at the offset within the compartment. The shelf shall be constructed of 3/ 16" (. 187 ") smooth aluminum plate. The shelf shall have a minimum 2" front lip for added strength and reinforcement and to accommodate optional plastic interlocking compartment tile systems. The shelf shall be capable of holding 100 lbs. Option Price: $ 313. 00 Option No. 5 An adjustable roll -out aluminum toolboard is being provided as an option. The toolboard shall be constructed of 3/ 16" (. 187 ") smooth aluminum plate with a sanded finish and be sized in height and depth as applicable. The toolboard shall be mounted on drawer slides, at the top and bottom, that will permit the board to roll out of the compartment for easier access to tools and /or equipment. The slide mechanisms shall have ball bearings for ease of extension and retraction operation and dependable service. The toolboard shall be mounted at top and bottom on adjustable tracking for ease of placement. The capacity rating shall be 250 lb. maximum at full extension. A pneumatic shock shall be utilized to secure the toolboard in the open or closed position. Option Price: $ 759. 00 Option No. 6 A hose tray constructed of 1/ 8" aluminum recessed into the front bumper extension is being provided as an option. The tray shall be located on either the driver side or the officer side. of the bumper outboard of the frame rail and shall be approximately 10" deep (9" to the top of the slats). One inch thick aluminum slats shall be included in the bottom of the hose tray to aid in the dissipation of water from the tray. The center bumper tray will have a diamond plate lid. The lid will be hinged and will be secured in the closed position by a latch and held open with a pneumatic shock. Option Price: $ 699. 00 7 jonal jappe-1 - £ IM paemV: 8£ Z0 wij Iloqung wojj lesodoad :; uauayae; ;y 40- 66 d = SunbeltFi re City of Fort Walton Beach C< MMO) Proposal for 78' Aerial Quint Option No. 7 An additional 2 -1/ 2" preconnect outlet with a manually -operated Akron valve is being provided as an option on the extended front bumper. The preconnect shall consist of a 2 -1/ 2" heavy -duty hose coming from the pump discharge manifold to a 2 -1/ 2" mechanical swivel hose connection to permit the use of the hose from either side of the apparatus and located officer' s side above the bumper area located on top of the gravel shield. The valve shall be an Akron 8800HD series with a 316 stainless steel ball and dual polymer seats for ease of operation and increased abrasion resistance. The valve shall have a self -locking ball feature using an automatic friction lock design to balance the stainless steel ball when in a throttle position with water flowing through it. The valve shall be of the unique Akron Swing -out design to allow the valve body to be removed for servicing without disassembling the plumbing. The discharge shall be supplied with a 3/ 4" bleeder valve assembly. The bleeder valve shall be installed to drain water from the gauge pressure line to prevent freezing of the line. The drain shall be controlled with a quarter -turn valve on the pump panel. The valve control shall be located at the pump operator panel and shall visually indicate the position of the valve at all times. All fabricated piping shall be a minimum of Schedule 10 stainless steel for superior corrosion resistance and decreased friction loss. Option Price: $ 1. 662. 00 0 3jonjl jappel - £ 60- 6 6 d=121 PJBmV : 8£ Z6) aal=l ; loqung wojl lesodo.ad 3uaua43ejjv Sunbelfire City of Fort Walton Beach Proposal for 78' Aerial Quint Optional Equipment per Specifications Ladder Belt, Gemtor Pompier 531 ( size S, M, L, or XL) Option Price: $ 140. 00 ( ea.) Nupla YPD -6 6' fiberglass handle pike pole with PAC brackets Option Price: $_ 150. 00 ( ea.) Nupla YPD -8 8' fiberglass handle pike pole with PAC brackets Option Price: $ 156. 00 ( ea.) Nupla YPD -12 12' fiberglass handle pike pole with PAC brackets Option Price: $ _ 163. 00 ( ea.) FireHooks 5' New York Hook with pry end with PAC brackets Option Price: $ 205. 00 (ea.) FireHooks 6' New York Hook with pry end with PAC brackets Option Price: $ 240. 00 (ea.) Amerex 33115 -lb. CO2 extinguisher with model 810 mounting bracket Option Price: $ 307. 00 (ea.) Amerex 411 20 -lb. ABC extinguisher with model 810 mounting bracket Option Price: $ 219. 00 ( ea.) Amerex 262 2. 5- gallon Class K extinguisher with mounting bracket Option Price: $ 231. 00 ( ea.) Amerex 8570 30 -lb. Class D extinguisher with mounting bracket Option Price: $ 411. 00 ( ea.) 0 Ional jappel - £ 40- 66 d = IH paeMV: 8£ Z0 aa! d Ilaqung woj1 lesodoad :} uawyoe; ;y Su nbeltFire City of Fort Walton Beach Proposal for 78' Aerial Quint CL Amerex 240 2. 5- gallon pressurized water extinguisher with model 810 bracket Option Price: $ 192. 00 (ea.) Council Tool C601` 36 6 -lb. flat head fiberglass handle axe with mount Option Price: $ 205. 00 (ea.) Council Tool C60P36 6 -lb. pick head fiberglass handle axe with mount Option Price: $ 209. 00 ( ea.) Council Tool 60PP 36" pinch point bar with South Park chrome -plated bracket Option Price: $ 102. 00 (ea.) Irons, including Irons Sling, 6 -lb. Council Tool flat head axe, Paratech 30" hooligan tool Option Price: $ 340.00 (ea.) FireHooks 24" bolt cutter

Download this text file with its original spacing ↓