READ ALONGSIDE THE SOURCE

Fort Walton Beach Council agenda — 10-09-12 regular-with petitions — reading text

Part 30 of 36. These parts divide the reading text for browsing; they are not the source document's page numbers.

Machine-extracted text — fwb-31383-original.pdf

Machine-extracted OCR text · Review label: Machine produced / unreviewed

Compare this copy with the preserved source. Review labels describe the recorded status of this file; they do not guarantee that the text is error-free. Spacing and line breaks are retained, with long lines wrapped to fit the screen.

Zoning Districts, of the Land Development Code, is hereby amended as follows: C. Site development standards for accessory buildings 1. An accessory building in the R -lE, R - I, R -2, YC, MX -1, and MX -2 zoning districts shall not exceed one ( 1) story, except where an accessory dwelling unit is approved in the second story above a garage. 2. An accessory building in the RAE, R -1, R -2, YC, MX -1, and MX -2 zoning districts shall have a roof pitch of 4: 12 or shall match the roof pitch of the principal building. 3. An itEeesseFy building in A. 0 1R, n 1 n O VC, env t and MX 2 zenin 41645 shall not mta,, d 600 s .. . The required side and rear yard setbacks for accessory buildings in the R -1E, R -1, R -2, YC, MX -1, and MX -2 zoning districts are shown below. a. Accessory buildings up to 200 s. f. in floor area shall be setback three ( 3) feet from side and rear property lines. b. Accessory buildings 4401R-t° `nn in excess of 200 s. f in floor area shall be setback seven and one -half (7 1/ 2) feet from side and rear property lines. e. Accessory buildings on a comer lot shall have a setback of fifteen ( 15) feet from the property line abutting a street. 43. An accessory building in the YC zoning district shall be setback from the rear property line ten ( 10) feet when the cumulative total square feet of floor area in all buildings is less than five ( 5) percent of the land area required for the wetland buffer. When the cumulative total square feet of floor area in all buildings Packet Pg. 113. 11. 3 ORDINANCE ( ID # 1999) exceeds five ( 5) percent, the rear setback shall be fifty (50) feet. 3A. Accessory buildings in the CF and CG zoning districts shall have a minimum rear yard setback of seven and one- half (7 %2) feet. Section 4. Amendment of Section 5. 01. 07, Storage Buildings, Storage Sheds, Greenhouses, and Detached Garages or Carports Section 5. 01. 07, Storage Buildings, Storage Sheds, Greenhouses, and Detached Garages or Carports, of the Land Development Code, is hereby amended as follows: A. Stenzage buildings, t feF+h i ceetien 5. 01. 07. 13. B. Storage buildings, storage sheds, and detached garages in the CG, CT4L, and MB zoning districts may that exceed 600 s. f. of floor area- must provided that brick veneer, stone, stucco, or other similar decorative materials areadded to the fagade on all sides of the building that are visible from the public right -of w - ay. C. Detached garages and carports shall not exceed twenty ( 20) feet in height. D. A detached garage eFearpert may be located within the front yard in the R -1 E zoning, provided that the detached garage or carport shall comply with the setback standards for the R -1E zoning district set forth in Section 4.01. 01. E. Storage buildings, storage sheds, greenhouses, detached garages, and carports shall not be located within any required buffer area, required landscaped area, required parking lot landscaping, storrawater management area, driveway, or easement. F. Vehicles shall not be used as storage buildings, utility buildings or other such uses. Vehicles includes: travel trailers, motor homes, and similar recreational vehicles; manufactured housing and mobile homes; trucks; cargo bailers; or other similar vehicles. Section 5. Amendment of Section 5. 01. 08, Fences, Hedges, and Walls Section 5. 01. 08( E), Fences, Hedges, and Walls, of the land Development Code, is hereby amended as follows: E. Height standards L Fence and wall height shall be measured from the natural grade at the base of the fence to the topmost part of the fence. 2. The maximum height for a fence on a lot line on property zoned R -IE, R -1, or R- 2 and adjacent to a property zoned for nonresidential use shall be six ( 6) feet. 3. Height standards are provided in Table 5. 01. 08. Table 5. 01. 08. Standards for Fence Heights. Zoning District Maximum Height in a Side Maximum Height in a Front or Rear Yard ( feet) Yard' ( feet) R - 1E 6 46 R -1 6 4 R -2 6 4 YC 6 4b CF 6 6 Packet Pg. 114 11 .3 ORDINANCE ( ID # 1999) CG 8 6 AM 6 6 AM -2 6 6 CTP 8 8 AM 8 6 REC 6 6 The 6omyanl is the area between the pnneipal snYnmre and the front property line. Section 6. Amendment of Section 5. 01. 11, Specific Requirements for Accessory Structures in the R -lE Zoning District Section 5. 01. 11, Specific Requirements for Accessory Structures in the R -lE Zoning District, of the land Development Code, is hereby amended as follows: The following accessory structures may be located within the rear yard of lots zoned R -1 E, provided that such structures are located a minimum of twenty fifittee- (-^25) ten 10 feet from the mean high water line or the seawall: pool and pool deck; gazebo; cabana with shower and/ or rest room facilities; outdoor kitchen, which may include a grill, wet bar, and associated storage; deck; paved or wooden terrace; and a walkway connecting to a dock, provided that the walkway is limited to a maximum of four ( 4) feet in width. Section 7. Amendment of Section 5. 03. 05, Temporary Signs Section 5. 03. 05, Temporary Signs, of the Land Development Code, is hereby amended as follows: Temporary signs shall comply with the following standards. A. Temporary signs are permissible subject to receipt of a temporary sign permit specifying type, size, location, and duration of placement. Temporary sign permits are be displayed for a period not exceeding fifteen ( 15) days B. Temporary signs shall not be placed in the public right -of -way. C. Temporary signs include banners flags and pennants Temporary signs shall not Flash, blink, spin, or rotate. D. The placement of temporary signs shall comply with the clear visibility requirements set forth in Section 6. 03. 00, and such signs shall not block traffic or pedestrian visibility, or constitute a vehicular or pedestrian traffic hazard. E. The placement of temporary signs shall not cause a public nuisance. F. Permissible temporary signs shall be firmly secured to the ground or to a building according to the requirements of the temporary permit. Temporary signs may be attached to or cover an existing permitted sign only for the period during which the temporary sign is permitted. Section 8. Effective Date This Ordinance shall take effect immediately upon approval by the City Council and signature of the Mayor. PackofPg. 115 11 .3 ORDINANCE ( ID # 7999) Adopted: Mike Anderson, Mayor Attest: Approved for legal sufficiency. Helen Spencer, City Clerk Hayward Dykes, City Attorney New language is underlined. Deleted language is stricken. Codification Instructions: Section I and 9 not codified. Sections 2, 3, 4, 5, 6, 7, and 8 codified and numbered as stated into the City of Fort Walton Beach Land Development Code. Mike Anderson, Mayor Attest: Approved for form, legal sufficiency Helen Spencer, City Clerk Hayward Dykes, Jr., City Attorney Additions are underlined; dplptiefls AFP ,..,,.- Packet Pg. 116 14. 1 City Council of Fort Walton Beach RECREATION MEMORANDUM To: Michael D. Beedie, City Manager From: Jeff Peters, Recreational and Cultural Services Director Date: October 9, 2012 Subject: Recreation Complex Discussion SIGNATURE BLOCK: Jeff Peters Completed 10/ 02/ 2012 4: 27 PM Carole Jones Completed 10/ 03/ 2012 8: 49 AM City Manager Pending City Council Pending Packet Pg. 11T F142 City Council of Fort Walton Beach 0 To: ENGINEERING & UTILITY SERVICES MEMORANDUM Michael D. Beedic, City Manager From: Michael Beedic, City Manager Date: October 9, 2012 Subject: Quote 2012 -0912 36 -Inch DI Pipe 1. 1. On August 14, 2012, City Council approved the execution of an Intedocal Agreement with Okaloosa County to construct the northern portion of the new sanitary sewer force main from Pump Station No. 1 to Okaloosa County' s Arberme Pritchett WRF. The County' s construction crews would be responsible for installing the new 36 -inch ductile iron force main from Bob Sikes Boulevard north to the Arbennic Pritchett WRF. 1. 2. On September 11, 2012, City Council awarded ITB No. 12 -027 for the Pump Station No. 1 Force Main and Reclaimed Water Main to Utility Service Company, Inc. Utility Service

Download this text file with its original spacing ↓