The Cortez is designed to meet the requirements of the sixty- inch
turning radius inside toilet room specified by the American with
Disabilities Act Requirements and Uniform Federal Accessibility
Standards as of the date of these specifications.
2. The Cortez is an all concrete design with a minimum 3/ 12
roof pitch.
5. 0 MATERIALS
A. Concrete - General
The concrete mix design will be designed to ACI 211. 1 to produce N
concrete of good workability.
I. Concrete will contain a minimum of 505 pounds of cement per
cubic yard. Cement will be a low alkali type 1 / 1I or III conforming
to ASTM C -150. n
2. Coarse aggregates used in the concrete mix design will conform to LL
ASTM C33 with the designated size of coarse aggregate # 67. a
3. Minimum water /cement ratio will not exceed . 45.
4. Air -entraining admixtures will conform to ASTM C260. Water m
reducing admixtures will conform to ASTM C494, Type A.
nu
B. Colored Concrete
wo.
H
1. Color additives will conform to ASTM C979. AI2 "x12 "x]" r
color sample will be available for customer approval. ii
2. The following will contain colored concrete:
a. Toilet building roof panels E
b. Building walls m
Screen panels
C.
a
3. The same brand and type of color additive will be
used throughout the manufacturing process.
4. All ingredients will be weighed and the mixing
operation will be adequate to ensure uniform dispersion of the
color.
CST incorporated 3 Dnc S 17
REV 12
Cortez Flush Toilet Specification
Packet Pg. 39
8. 2. d
C. Cold Weather Concrete
1. Cold weather concrete placement will be in accordance
with ACI 306.
2. Concrete will not be placed if ambient temperature is
expected to be below 35 degrees F. during the curing period unless
heat is readily available to maintain the surface temperature of the
concrete at least 45 degrees F.
3. Materials containing frost or lumps of frozen materials will
not be used.
D. Hot Weather Concrete
The temperature of the concrete will not exceed 95 degrees F. at the time
of placement. When the ambient reaches 90 degrees F. the concrete will
be protected with moist covering.
E. Concrete Reinforcement
o2
1. All reinforcing steel will conform to ASTM A615. All
welded wire fabric will conform to ASTM Al 85. a
a
2. All reinforcement will be new, free of dirt, oil, paint,
grease, loose mill scale and loose or thick Dust when placed. n
3. Details not shown of drawings or specified will be to ACI318. LL
4. Steel reinforcement will be centered in the cross -sectional 6
n
area of the walls and will have at least 1" of cover on the under
surface of the floor and roof.
5. The maximum allowable variation for center -center spacing of
reinforcing steel will be' /z ".
6. Full lengths of reinforcing steel will be used when possible. When n
m
splices are necessary on long runs, splices will be alternated from N
opposite sides of the components for adjacent steel bars. Lap bus r
0
4 or smaller a minimum of 12 ". Lap bars larger than # 4 a
minimum of 24 bar diameters. c
7. Reinforcing bars will be bent cold. No bars partially embedded in vE
concrete will be field bent unless approved by the customer. om
a
F. Sealers and Curing Compounds
I. Curing compounds, if used, will be colorless, complying with
ASTM C309, type I or 1 - D.
2. Weatherproofing sealer for exterior of building will be a clear
water repellent penetrating sealer.
CAT IncoToremd 4 Doc 5. 1)
Cortez Flush Toilet specification REV 12
Packet Pg. 40
8. 2. d
G. Caulking, Grout, Adhesive and Sealer
I. Caulking service temperatures from - 40 to + 140 degrees
Fahrenheit.
2. Interior and exteriorjoints will be caulked with a paintable
polyurethane sealant.
3. Grout will be a non- shrink type and will be painted to match the
color of surrounding concrete as nearly as possible.
4. Cement base coating is formulated with a very fine aggregate
system and a built in bonding agent.
H. Paint
All paints and materials will conform to all Federal specifications D
or be similar " top- of-the- line- components". Paints will not contain ' q
a.
more than .06 percent by weight of lead.
2. Type of paints for toilets
a. Inside concrete surfaces
c
as
I Interior floors will be a 2 component, catalyzed,
water borne polyamide epoxy with a micronized
polymer additive to provide uniform slip resistant
texture. The color will be gray. a
II Interior walls and ceilings will be a modified LL
m
acrylic, water repellent penetrating stain. The color
will be white followed by a clear acrylic anti -graffiti a
sealer. m
b. Metal surfaces both inside and out
I DTM ALKYD on
C. Exterior concrete surfaces uo.
WW
I Exterior slab will be clear sealer N
it Exterior walls and roof will be a water repellent r
penetrating stain in the same color as the walls 00
or roof followed by a clear acrylic anti -graffiti
sealer.
LuEY