garbage cans). .
5. There must be a minimum of one
receptacle at work surface which must be ground fault
interruption ( GFI) protected if within 6' of the sink, one non- GFI receptacle adjacent to
the refrigerator, and one
ceiling fixture. All electrical work shall conform the Florida
Building Code (latest edition).
Bathroom Facilities: Bathroom facilities must be located in the unit,
a separate and
in nature and shall include the
private room
following:
1. Water Closets: Each dwelling unit shall contain a water closet
supplied with running
water in an enclosed area not less than
thirty (30) inches in width not less than eight ( 18)
inches clear space in from of the water closet therein and must be in
proper working
condition.
2. Bathing: Each dwelling unit shall contain a bathtub or shower with a supply of hot and
cold running water in proper
working condition.
3. Lavatory: Each dwelling unit shall contain a lavatory with a sink trap and a supply of hot
and cold running water and must be in
proper working condition. The lavatory shall be
located in the same room as the water closet or
immediately adjacent thereto.
4. A minimum of one GFI
receptacle and one permanent wall or ceiling fixture.
All plumbing work shall be in accordance with the Florida
Building Code (latest edition) as well
as all local code
requirements.
Room Arrangements: Access to all
parts of a dwelling unit shall be possible without passing
outside the dwelling unit, or passing
throughanother dwellingunit.
A bathroom shall not be used as the
only passageway to a habitable room, hall, basement, or
dwelling unit.
A utility room, sleeping room, closet, or
storage room shall not be used as the only passageway
to a habitable room or to a
dwelling unit.
Habitable rooms below grade: Habitable rooms below
grade or partially below grade shall
comply with all the requirements of these standards pertaining to habitable rooms.
MEANS OF EGRESS
Not less than one exit, sized in accordance with the Florida
Building Code (latest edition), as
provided herein shall be provided for each dwelling unit.
Every sleeping room shall have at least one operable window or exterior door approved for
emergency egress or rescue, as per the Florida Building Code (latest edition). The window or
exterior door must be operable from the inside to a full clear
opening without the use of separate
toolS'. Windows that are accessible. from the outside, such as basement,
first floor and fire escape
windows must be lockable ( such as window units with sash
pins or sash locks and combination
windows with latches). Exterior doors must be lockable. Where windows are
provided as a
means of egress or rescue
they shall have a sill height in accordance with the Florida Building
Code (latest edition) and have a minimum net clear
opening in accordance with the Florida
Building Code (latest edition). The minimum net clear opening dimension should be in
accordance with the Florida
Building Code (latest edition).
Each sleeping room or room with.a
required exit door that has security bars, grilles, grates or
similar devices installed shall have at least one
emergency escape and rescue opening as per the
Florida Building Code (latest edition). Bars, grills, grates, or screens placed over windows must
be releasable or removable from the inside without the use of a
key, tool, or excessive force as
per the Florida Building Code (latest edition).
FIRE RESISTANCE REQUIREMENTS
Dwelling- garage Separation: The common wall or floor-ceiling, if any, between a garage and a
dwelling shall be protected as required by the Florida Building Code (latest edition) for new
construction.
Smoke Detector:
Each dwelling unit must include at least one
battery- operated or hard- wired smoke detector, in
proper working condition, on each level of the unit
including basement but excluding
craw lspaces and unfinished attics.
Smoke detectors must be installed in accordance with and
meet the requirements of the National Fire
Protection Association Standard (NFP A) 74 or
successor standards. It should be located, to the
extent practicable,in a hallway adjacent to a
bedroom. If the unit is occupied by
hearing- impaired persons, smoke detectors must have an
alarm system, designed for
hearing- impaired persons, as specified in NFP A 74 or successor
standards, in each bedroom
occupied by a hearing- imp~ired person, connected to the smoke
detector located in the hallway. Smoke detectors must be
installed in accordance with local code
requirements.
CONSTRUCTION
General Requirements:
All components of the
building shall be in sound conditiop. or shall be restored to a sound
condition.
Roofs should be given particular attention in
any inspection to be certain of the long tenn
serviceability of the system. Roofs must be structurally sound and weather tight.
Provisions shall be made for roof drainage as
required by applicable code or ordinance.
All exterior walls shall be weather
tight. The surface of the-exterior walls must not have any
serious defects such as serious
leaning, buckling, sagging, large holes or defects that may result
in air infiltration or vermin infestation.
All new construction shall be in accordance with the
Florida Building Code (latest edition).
Interior Finish:
Floors: Floors shall comply with the
following provisions:
1. Floors .must not have any serious defects such as severe
bulging o~ leaning, large
holes, loose surface materials, severe
buckling, missing parts or other severe damage.
2. Floors or habitable or occupiable rooms in basements or cellars
shall be surfaced or
paved in an acceptable manner when in direct contact with the grade.
3. Floors in bathroom and water closet
compartments and kitchens shall be impervious
to water, and shall be constructed so as to
pennit the floor to be easily kept in a clean
and sanitary condition. The floor finish shall be of a durable,
waterproof,
non-
absorptive material such as asphalt, vinyl-plastic, rubber tile, ceramic tile, terrazzo,
linoleum, concrete or other approved material.
4. Finish floors in habitable rooms 'or common
spaces shall meet the requirements of the
Florida Building Code ( latest edition) for new construction.
Walls and Ceilings: Interior walls and
ceilings shall confonn to the following requirement:
1. Walls and ceilings must not have
any serious defects such as severe bulging or leaning,
large holes, loose surface materials, severe buckling, missing parts or other' serious
damage.
2. The finished surfaces shall not have excessive detrimental or
unsightly irregularities or
cracking.
3. The finish surfaces shall be
waterproof and hard surfaced in areas of rooms or spaces.
subject to direct moisture contact, such as bath and shower areas. Kitchen and baths shall
be painted or papered to provide a washable finish surface.
4. Existing interior finish surfaces containing any lead content shall be removed and
replaced or covered with a lead- free material utilizing an approved lead- hazard reduction
activity which uses safe wor~ practices and clearance as required by Title X of the 1992
Housing and Community Development Act (24 CFR Part 35).
Doors an~ Openings: Interior doors and
openings shall confonn to the following requirements:
1. Doors and openings shall be six ( 6) feet with (8) inches
minimum in height with
minimum widths as shown in the
following Table 1:
TABLE 1
MINIMUM DOOR WIDTHS
Room or Space Minimum Door Width
Habitable or occupiable rooms 2 ft.6 in.
Bathrooms, water closet compartments,
storage 2ft. 0 in.
closets ( over 4, sq. ft. in area) ..
Exit access or service stairs 2 ft.0 in.
Exit doors
3 ft. 0 in.
Handicap unit doors . 2 ft. 8 in. free openin2
2. At least one ( 1) scuttle or access hatch to attic or crawl