fren rm rn ee Keyed Notes {2) CAT Se or 6 UTP CABLES ROUTED FROM THE TSA IT CABINET TO EACH DEVICE AS NOTED. TERMINATE ALL CAT 5e or 6 CABLE ON THE OUTLET END WITH A MODULAR RI-45 CAT 3e or 6 RATED 5688 JACK CONTAINED IN POKE OR FACEPLATE AS NOTED ON THE DRAWINGS. CONTRACTOR TO TERMINATE TSA CABINET END TO A CAT 5e or 6 RATED MODULAR RACK MOUNTED PATCH PANEL. @) CONTRACTOR TO PROVIDE NEW PATCH PANEL{S) IN QUANTITY AS INDICATED ON THE DRAWINGS, PATCH PANEL SHALL HAVE A RATING OF CAT Se or 6. @) EXISTING TSA IT CABINET, SHOWN FOR REFERENCE ONLY. Page 37 of 39 HSTS04-13-H-CT1161 Figure 2 illustrates all of the equipment that must be connected to the IDF IT cabinet for a CBIS where the EDS machines are already networked together. When the EDS machines are networked together (i.e, MUX, NEDS, etc.), the connection only needs to be made to the EDS Network Server(s). Figure 2 NETWORKED CBIS CONFIGURATION TSA IT Cabinet (Existing) eps CAT Se or ~ Network» | Server Keyed Notes {2} CAT 5e or 6 UTP CABLES ROUTED FROM THE TSA IT CABINET TO EACH DEVICE AS NOTED. TERMINATE ALL CAT Se or 6 CABLE ON THE OUTLET END WITH A MODULAR RJ-45 CAT 5e or 6 RATED S68B JACK CONTAINED IN POKE OR FACEPLATE AS NOTED ON THE DRAWINGS. CONTRACTOR TO TERMINATE TSA CABINET END TO ACAT Se or 6 RATED MODULAR RACK MOUNTED PATCH PANEL. @) CONTRACTOR TO PROVIDE NEW PATCH PANEL(S) IN QUANTITY AS INDICATED ON THE DRAWINGS. PATCH PANEL SHALL HAVE A RATING OF CAT 3e ar 6. EXISTING TSA IT CABINET, SHOWN FOR REFERENCE ONLY. EDS NETWORK CABLING TO BE PROVIDED BY EDS MANUFACTURER, ee At a minimum, the following guidelines should be considered when designing a new CBIS or reconfiguring an existing CBIS. e Ifan existing TSA IT cabinet is within 295 feet of the CBIS: o Verify that the existing switches have sufficient open ports to accommodate the required number of drops o Notify TSA OIT FRM if the existing switch capaCOUNTY will not accommodate the required number of drops so that additional equipment can be procured. o Punch down cabling from the individual CBIS devices in the patch panel of the IT cabinet Page 38 of 39 If Cabinet e Ifthere is no IT cabinet within 295 feet of the CBIS: 10) ie) HSTS04-13-H-CT1161 Install an appropriate IT cabinet. Refer to Figure 3 for the IT cabinet specifications Run fiber optic cable from the IT cabinet to an existing TSA IT cabinet Notify TSA OIT FRM so that additional equipment can be procured. Punch down cabling from the individual CBIS devices in the patch panel of the IT cabinet Initiate IMAC group to install jumper cables from the patch panel to the switch and activate port Size 24H 24.0°H x 27.3°W x 30.0") Weight: 97 ibs Siza 36H 36.0°H x 27.3°W x 30.0°D Weight: 724 ibs Size 48H 48.0°H x 27.3°W x 30.0°D Weight 151 Ibs Size 60H 60.0°H x 27.3"W x 30.00°D Weight: 246 Ib: Pole, 3-Wit i == : Ree neon Roca adhere to all applicable local codes and standards, Recommend Size 72H ¢ 6KVAUPS consultation with the Field Regional Manager (FRM) when 72.0°H x 27.3°W x 30.0°D * 8° power cord from the IT cabinet to the considering a wall-mounted alternative. Weight: 274 ibs receptacle ‘1 or more per checkpaint depending on size Figure 3 IT CABINET For 24H, 36H and 48H: + Dedicated * 30A, 125V, 3KVA/Cabinet 2Pole, 3-Wire Grounding NEMA LS-30R Receptacte SKVA UPS 6” power cord from the IT cabinet to the receptacle For 6OH and 72H: « Dedicated 30A, 208V. SKVA/Cabinet . Size patch panels ta accommodate ail TSA data auats at the checkpoint pilus 100% spares, minimum. Size giga bit network switch to accommodate ail data ouilels in checkpoint plus 10%. Provide a minimum of faur pair single mode: fiber optic cable from (T cabinet to the TSA main distribution frame. . * 30" front and rear access is required. These cabinets will receive ali data communication lines fram the SSCP. so the cabinet shoutd be located as close to the SSCP as possible, bul in a secure location. Careful consideration needs to be given to the IT cabinet location because the exhaust fan for coating can be foud when located in a confined space with TSA oF airport personnel. Equipment racks can be loaded into the cabinet from tha front or the back at tha focation where the cabinat is installed. Allhough Rot required, side access would improve rack accessibility and TSA personnel mobility around the cabinet. Refer to Program of Requirements dated July 2008, Section III-D for tabeting, cable management and acministration of IT cabinet. Refer to Program of Requirements dated July 2005, Section lil-D for acceptance tasting of {T circuits, Wall-maunted cabinets are an option in some instances, but must Isometric View REFERENCE POINT * PLAN VIEW ACCEPTABLE AREA FOR RECESSED, SURFACE, FLUSH, OR POWER POLE DEVICE Page 39 of 39

Download this text file with its original spacing ↓