D. The placement of temporary signs shall comply with the clear visibility requirements
set forth in Section 6. 03. 00, and such signs shall not block traffic or pedestrian
visibility, or constitute a vehicular or pedestrian traffic hazard.
E. The placement of temporary signs shall not cause a public nuisance.
F. Permissible temporary signs shall be firmly secured to the ground or to a building
according to the requirements of the temporary permit. Temporary signs may be
attached to or cover an existing permitted sign only for the period during which the
temporary sign is permitted.
5. 03. 06 Permissible Permanent On -Site Signs
Permanent on -site signs shall be erected, placed, constructed, located, or installed only in
compliance with the standards set forth in this section.
A. Standards for number, type, and size of signs are set forth in Table 5. 03. 06.
B. Signs located on property in the R - 1 and R - I E districts shall not exceed a total of four
4) square feet in area.
1),, I I' lpmrni mandal' k Page 6 - 22
LE
k!k!))
zE fJ!fJ!
f!f!
a s 1
Pori AAahon [ tench I INA1. I and
C. Lighting
External lighting of signs is allowed, subject to the following standards:
1. The light source is directed onto the sign face.
2. The light source is shielded to prevent spill -over or glare onto adjacent properties.
3. Within the DDOD, neon signs are permissible as interior window signs. The
maximum sign area devoted to a neon sign shall not exceed four (4) s. f. and shall
be included in the calculation of maximum sign area for a permissible window
sign. Sandwich signs are also permissible in the DDOD.
D. Signs that electronically produce changeable copy are permitted provided they flash
or move or otherwise change at intervals consistent with the Florida Department of
Transportation standards.
E. Measurement
1. Where a sign is composed of letters or pictures attached directly to a facade, wall,
window, door, awning, monument sign, or freestanding sign, and the letters or
pictures are not enclosed by a border or trimming, the sign area shall be the area
within the smallest rectangle, parallelogram, triangle, circle, semicircle, or a
combination of any of these geometric shapes, the sides of which touch the
extreme points of the letters or pictures as a whole.
2. Where a sign is composed of letters or pictures enclosed by a border or trimming,
the sign area shall be the area within the border or trim.
3. In cases where material is displayed in a random or unconnected manner without
organized relationship of the components, each such component shall be
considered a single sign.
4. The area of a freestanding sign shall include the area of the outside frame, but not
of the supporting structure.
F. Determining the number of signs
1. The number of signs shall be the number of structures with a sign face.
2. A double -faced projecting or freestanding sign shall be construed as having the
area of a single face, provided that the sign faces are placed back to back and are
at no point more than four (4) feet apart.
G. Specific requirements for commercial establishments with street frontage at the
intersection of two ( 2) streets.
1. The owner of the establishment may elect in writing to display only one ( 1)
freestanding sign equal to seventy -five ( 75) percent of the total maximum
aggregate sign area for the two ( 2) street frontages, instead of displaying one ( 2)
freestanding sign per street frontage.
2. Large scale commercial centers shall be exempt from this requirement.
H. Specific standards for pennants
1. Pennants are permissible for multi- tenant centers and car dealerships.
2. Pennants shall be identified in a sign plan.
3. Pennants shall be part of a coordinated decorative scheme and shall not exceed six
6) square feet in area.
4. Pennants shall be attached to freestanding poles or freestanding light fixtures.
5. 03. 07 Flagpoles
Flagpoles are permissible as an accessory structure provided the following standards are met:
V...... m,n, Tcmpora y, Special I,,, I' a" - 24
I.,, t o, ;d ton neaeh II%X1, l and Do clopum nt('" de
A. Flagpoles shall be located a minimum of three ( 3) feet from a side or rear property
line.
B. Flagpoles shall be located a minimum of five ( 5) feet from a front property line.
C. Flagpoles shall not exceed 200 feet in height.
5. 04.00 SUPPLEMENTAL STANDARDS FOR SPECIFIC USES
5. 04. 01 Generally
A. This section sets forth standards for specific uses that are permissible subject to
supplemental standards. Uses that are permissible subject to these supplemental
standards are identified by the letter " S" in Table 2. 03. 02.
B. Where there is a conflict between a standard applicable to the zoning district in which
the use is located and the supplemental standards set forth below, the more restrictive
standard shall apply.
5. 04. 02 Townhouses
A. A townhouse is a single -family dwelling unit attached horizontally by a common or
party wall to one ( 1) or more dwelling units.
B. A townhouse development shall be designed and developed as a single, integrated
development project. The development and the individual townhouse units shall
comply with the following standards.
1. A townhouse shall be not less than two (2) stories.
2. An individual townhouse unit shall be located on a platted lot, established in
compliance with the standards for subdivisions set forth in Section 4.07. 00.
a. The minimum lot area for an individual townhouse unit is 1, 400 s. f.
b. The minimum lot width for an individual townhouse unit at the end of a group
of units and adjacent to a street on the side property line shall be twenty -five
and one -half (25'/ 2) feet.
c. The minimum lot width for all individual townhouse units, other than the end
unit, is eighteen ( 18) feet.
3. The structures containing townhouse units shall comply with the zoning standards
setting forth maximum impervious surface, maximum height, and maximum
density on a development site.
a. The minimum setback from a side property line shall be seven and one- half (7
2) feet.
b. There shall be a maximum of six ( 6) individual townhouse units within one
structure.
c. Each individual townhouse unit shall have a private entrance.
d. The front faqade of each structure shall include projections.
4. Where a townhouse development abuts property zoned or used for single -family
or duplex development, a fence, six ( 6) feet high, shall be provided. The finished
side of the fence shall face outward. No fence is required where an alley
separates the townhouse development from the single -family or duplex
development Each portion of the fence shall be the property of the owner of the
townhouse lot on which it is located; such owner is responsible for maintenance
of that portion of the fence.
5. Standards for refuse containers
icc" on p. l'cugnn arf, Special fcrs Page;
I, it o ahoa h, idr HN %I Lend Re * elonmenl Code
a. Individual refuse containers shall be provided for each townhouse and all such
containers shall be located together on a paved area not larger than five ( 5)
feet by five (5) feet.
b. The refuse area shall be setback a minimum of twenty ( 20) feet from any
property line. Where an alley is provided, the dumpster or refuse area may be
located adjacent to the alley.
c. The dumpster or refuse area shall be screened in compliance with the
standards set forth in Section 5. 01. 061).
5. 04.03 Junkyards, Scrap Metal Yards, and Recycling Facilities
A. This section is intended to address facilities where worn out and discarded materials
are collected, accumulated, stored, disassembled, processed, or handled.
B. Materials may include:
1. Scrap metals such as von, steel, brass, copper, aluminum, tin, lead, or other base
metals;
2. Plastics;
3. Rubber;
4. Glass;
5. Paper or cardboard;
6. Inoperable machinery, equipment and parts;
7. Inoperable vehicles or parts; and
8. Other similar waste or scrap materials.
C. Collection, storage, or handling of hazardous materials shall comply with State and
Federal standards.
D. The outdoor portion of the facility shall be screened with a fence, wall, or landscaped
buffer.
I. The facility shall not be visible from a public right-of-way or from land zoned to
allow residential use.
2. The facility shall be enclosed with a fence or wall not less than eight ( 8) feet and
not more than ten ( 10) feet high. The fence or wall shall be solid. The finished
side shall face outward.
3. Where a landscaped buffer is provided, the plants shall include evergreen trees
and shrubs.
a. The planting strip shall be a minimum of fifteen ( 15) feet wide and located on
the perimeter of the site.
b. Plant materials shall comply with the specifications set forth in Section
4. 08. 03.