applicable to principal buildings shall not prohibit or restrict
the installation of a retaining wall.
5. Fences, perimeter hedges, and walls shall not be located within the required clear
visibility area designed in Section 6. 03. 00.
6. Fences, perimeter hedges, and walls shall not obstruct, hinder, or impede the safe
movement of pedestrian, bicycle, or vehicular traffic.
B. Materials and appearance requirements
1. Fences and walls shall be constructed of wood, masonry, stone, wrought iron,
chain link, vinyl, or composite materials.
2. The following fence types are prohibited: wire and welded wire.
3. All fences shall be installed with the finished side facing outward.
4. Fences located at the front yard setback or in the area between the front yard
setback and the front property line shall not be solid and shall be a minimum of
fifty (50) percent open.
5. A fence installed for security purposes for industrial uses- may include barbed
wire, provided that the barbed wire is eight ( 8) feet above ground.
C. Electrical fencing may be installed for security purposes and shall meet the following
standards:
1. Electrical fencing may be installed on the top of a fence in the CG, CTP, or MB
Land Dc. rlon.. i" A Cod,
zoning districts, provided that the electrical fencing is a minimum of six ( 6) feet
above the ground.
2. Electrical fencing may be installed in residential areas provided that such fencing
shall be limited to rear yards and shall be contained within a fence structure.
3. All electrical fencing shall be accompanied by signs to provide a warning of the
type of fence and the voltage of the fence. Warning signs in shall be placed at
each corner of the enclosed area; additional signs shall be placed fifteen ( 15) feet
apart along the entire fence. Warning signs shall not exceed four ( 4) square feet
in area each.
D. Mandatory fencing
Where the YC zoning district abuts property zoned to allow residential use, a fence or
hedge shall be installed on or at the abutting property line. The fence or hedge shall
be opaque and shall be a minimum of six ( 6) feet in height.
E. Height standards
1. Fence and wall height shall be measured from the natural grade at the base of the
fence to the topmost part of the fence.
2. The maximum height for a fence on a lot line on property zoned R -IE, R -1, or R-
2 and adjacent to a property zoned for nonresidential use shall be six ( 6) feet.
3. Height standards are provided in Table 5. 01. 08.
Table 5. 01. 08. Standards for Fence Heights.
Maximum Height in a Maximum Height in a
Zoning District Side or Rear Yard (feel) Front Yard ( feel)
R -lE 6 4
R -1 6 4
R -2 6 4
YC 6 4
CF 6 6
CG S 6
MX- 1 6 6
MX -2 6 6
CTP B 8
MB 8 6
REC 6 6
The from yard is the area between the principal structure and the born propcoy line.
5.01. 09 Building Attachments (awnings, porches, carports, etc)
A. Awnings
All awnings placed on or attached to buildings in the R - IE, R -1, R -2, CG, MX -1,
MX -2, CTP, and MB zoning districts shall meet the following standards:
1. The front edge of the awning in the R -1E, R- 1, R -2, CG, MX -1, MX -2, and MB
zoning districts may encroach into the required setback, provided that the front
edge of the awning shall be a minimum of four (4) feet from the property line,
2. An awning located on a building in the CTP zoning district shall not encroach into
a required setback.
Dmclopmcnl Standards Pog, 5 - I t
Fors oa1c". Beach D" doonu•ot ( ode
3. All supporting poles or structures shall be located outside the public right -of -way.
4. The lowest part of the awning, including
supporting poles, structures, or other framework,
shall be a minimum of eight ( 8) feet above the
ground or paved surface under the awning.
B. Porches
Porches may be included in the initial construction
4'N
M
or added to a principal building in any zoning
district, subject to the following standards:
1. An existing porch in R -IE, R -1, and R -2 zoning
districts may encroach into a required front or Figure 5. m Location of
rear yard setback up to ten ( 10) feet- A roof Arcno gs
Awinng
overhang of up to eighteen ( 18) inches is
permissible. An encroachment into a required side yard setback is prohibited.
2. An existing porch that encroaches into a required yard setback may be enclosed
with transparent insect screening so long as the original design features, such as
railings, columns, and other building details are maintained.
3. An existing porch that does not encroach into a
required yard setback may be enclosed with Iirr x.
i
walls, windows, and/ or doors. The building -- w
materials, roof style and materials, architectural
style, and color of the porch enclosure shall be
consistent with the principal building, such that
the porch forms an integral part of the principal
building. I m
4. A porch may be added to an existing principal
building, provided it complies with the Figure 5.01. 09 on. Porch
encroachment into a required
following standards:
setback
a. A proposed porch shall be compatible with
the principal building in scale and mass.
b. The porch shall not be enclosed except with screen.
c. The porch may encroach into a required front or rear yard setback in R -IE, R-
1, and R -2 zoning districts up to ten ( 10) feet, provided that such
encroachment is not more than ten ( 10) feet, measured to the outermost edge
of the porch. A roof overhang of up to eighteen ( 18) inches or the depth of the
roof overhang on the existing principal structure, whichever is less, is
permissible
d. A roof overhang of up to eighteen ( 18) inches or the depth of the roof
overhang on the existing principal structure, whichever is less, is permissible.
e. A porch in all remaining zoning districts shall comply with the required front
and rear yard setbacks.
f. A porch shall not encroach into any required side yard setback.
g. The building materials, roof style and materials, architectural style, and color
of the porch shall be consistent with the principal building, such that the porch
forms an integral part of the principal building.
C. Carports
Ucrcloprnenl standard, Pm „ c ; - 12
I oil Dalton nwch 1 : uu1 D, dopntanl Code
Attached earpons may be included in the initial construction or added to a principal
building in any zoning district, subject to the following standards:
1. A carport shall be attached to the principal
building on at least one ( 1) side.
2. The support columns shall be consistent with the
materials, style, and color of building materials
for the principal building. Notwithstanding this
provision, decorative wrought iron columns may
be used.
3. The lowest structural member of the carport
shall be a minimum of eight ( 8) feet and a Carport
Figure 5. 01. 09
maximum of ten ( 10) above the ground. height requiremuireni ents
4. The area under the carport shall not exceed 600
s. f.
5. The area under the carport shall be paved or a stabilized all- weather surface.
6. A carport located in a side or rear yard shall be setback at least three ( 3) feet,
measured to the outermost edge of the carport,
including the eave. m
7. A carport may be located within a required front
yard setback in a R -IE, R -1, or R -2 zoning iv
w
district provided that such encroachment is not
more