READ ALONGSIDE THE SOURCE
Okaloosa County BOCC — February 4, 2014 — Shalimar (229025) AWS SA (Passing) 12-3-13 — reading text
Part 8 of 10. These parts divide the reading text for browsing; they are not the source document's page numbers.
Machine-extracted text — 93-Shalimar _229025_ AWS SA _Passing_ 12-3-13.pdf
Machine-extracted OCR text · Review label: Machine produced / unreviewed
Compare this copy with the preserved source. Review labels describe the recorded status of this file; they do not guarantee that the text is error-free. Spacing and line breaks are retained, with long lines wrapped to fit the screen.
Date
Destek Engineering, LLC
5150 Stilesboro Road, Ste 510 Shalimar 17:18:39 11/07/13
Kennesaw, GA 30152 Client Designed by
Phone: 770-693-0835 PM&A
FAX: Ahmet Colakoglu
10 Yes 5 0.00000001 0.00064826
11 Yes 5 0.00000001 0.00021324
12 Yes 5 0.00000001 0.00062126
13 Yes 5 0.00000001 0.00020148
14 Yes 4 0.00000001 0.00050569
15 Yes 4 0.00000001 0.00025747
16 Yes 5 0.00000001 0.00063986
17 Yes 5 0.00000001 0.00020954
18 Yes 5 0.00000001 0.00063722
19 Yes 5 0.00000001 0.00020843
20 Yes 4 0.00000001 0.00041820
21 Yes 4 0.00000001 0.00020643
22 Yes 5 0.00000001 0.00062196
23 Yes 5 0.00000001 0.00020176
24 Yes 5 0.00000001 0.00064903
25 Yes 5 0.00000001 0.00021355
26 Yes 4 0.00000001 0.00003893
27 Yes 4 0.00000001 0.00022769
28 Yes 4 0.00000001 0.00023026
29 Yes 4 0.00000001 0.00003584
30 Yes 4 0.00000001 0.00024837
31 Yes 4 0.00000001 0.00022017
32 Yes 4 0.00000001 0.00003895
33 Yes 4 0.00000001 0.00023892
34 Yes 4 0.00000001 0.00023595
35 Yes 4 0.00000001 0.00003587
36 Yes 4 0.00000001 0.00022086
37 Yes 4 0.00000001 0.00024945
Maximum Tower Deflections - Service Wind
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. ° °
L1 181.25 - 135.25 29.683 34 1.5873 0.0028
L2 139.25 - 87.25 16.866 34 1.2440 0.0013
L3 92.4167 - 48.4167 6.948 34 0.7600 0.0007
L4 54 - 1 2.234 34 0.3978 0.0003
Critical Deflections and Radius of Curvature - Service Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ° ° ft
181.25 DB810K 34 29.683 1.5873 0.0028 38030
180.38 DB810K 34 29.399 1.5805 0.0028 38030
179.50 DB810K 34 29.116 1.5738 0.0027 38030
176.00 (2) Antel WPA-80063-8CF with 34 27.985 1.5468 0.0026 36219
pipe
143.50 (2) X7C-FRO-440 with pipe 34 18.028 1.2822 0.0014 5036
138.00 (3) LPA-70060-8CF-EDIN-X with 34 16.533 1.2326 0.0013 4609
Pipe
Job Page
RISATower 010010333 11 of 13
Project Date
Destek Engineering, LLC
5150 Stilesboro Road, Ste 510 Shalimar 17:18:39 11/07/13
Kennesaw, GA 30152 Client Designed by
Phone: 770-693-0835 PM&A
FAX: Ahmet Colakoglu
Maximum Tower Deflections - Design Wind
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. ° °
L1 181.25 - 135.25 181.457 20 9.7170 0.0167
L2 139.25 - 87.25 103.275 20 7.6233 0.0081
L3 92.4167 - 48.4167 42.597 20 4.6609 0.0043
L4 54 - 1 13.700 20 2.4403 0.0021
Critical Deflections and Radius of Curvature - Design Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ° ° ft
181.25 DB810K 20 181.457 9.7170 0.0167 6536
180.38 DB810K 20 179.730 9.6765 0.0165 6536
179.50 DB810K 20 178.003 9.6360 0.0163 6536
176.00 (2) Antel WPA-80063-8CF with 20 171.103 9.4736 0.0155 6225
pipe
143.50 (2) X7C-FRO-440 with pipe 20 110.372 7.8608 0.0086 857
138.00 (3) LPA-70060-8CF-EDIN-X with 20 101.242 7.5518 0.0079 782
Pipe
Compression Checks
Pole Design Data
Section Elevation Size L Lu Kl/r A Pu Pn Ratio
No. Pu
2
ft ft ft in lb lb Pn
L1 181.25 - TP28.2552x15x0.4 46.00 0.00 0.0 34.3929 -8927.37 2535100.00 0.004
135.25 (1)
L2 135.25 - 87.25 TP41.2867x26.3026x0.53 52.00 0.00 0.0 67.0146 -23060.90 4939650.00 0.005
(2)
L3 87.25 - TP51.4168x38.7379x0.54 44.00 0.00 0.0 85.6671 -38742.70 6220260.00 0.006
48.4167 (3)
L4 48.4167 - 1 (4) TP64.0002x48.7279x0.6 53.00 0.00 0.0 122.489 -68084.90 8428920.00 0.008
0
Pole Bending Design Data
Section Elevation Size Mux Mnx Ratio Muy Mny Ratio
No. Mux Muy
ft lb-ft lb-ft Mnx lb-ft lb-ft Mny
L1 181.25 - TP28.2552x15x0.4 796130.83 1369516.67 0.581 0.00 1369516.67 0.000
135.25 (1)
Job Page
RISATower 010010333 12 of 13
Project Date
Destek Engineering, LLC
5150 Stilesboro Road, Ste 510 Shalimar 17:18:39 11/07/13
Kennesaw, GA 30152 Client Designed by
Phone: 770-693-0835 PM&A
FAX: Ahmet Colakoglu
Section