READ ALONGSIDE THE SOURCE
Okaloosa County BOCC — February 4, 2014 — Shalimar (229025) AWS SA (Passing) 12-3-13 — reading text
Part 1 of 10. These parts divide the reading text for browsing; they are not the source document's page numbers.
Machine-extracted text — 93-Shalimar _229025_ AWS SA _Passing_ 12-3-13.pdf
Machine-extracted OCR text · Review label: Machine produced / unreviewed
Compare this copy with the preserved source. Review labels describe the recorded status of this file; they do not guarantee that the text is error-free. Spacing and line breaks are retained, with long lines wrapped to fit the screen.
STRUCTURAL ANALYSIS REPORT
MONOPOLE
Prepared For:
PM&A
30 Mansell Court, Suite 103
Roswell, GA 30076
Verizon Wireless Cell Site Name: Shalimar
1250 N Eglin Pkwy
Shalimar, FL 32579
Destek Job No: 010010333 November 7, 2013
DESTEK ENGINEERING, LLC
5150 Stilesboro Road, Suite 510, Kennesaw, GA 30152 ‐Tel: (770) 693‐0835
Shalimar – Structural Analysis
CONTENTS
1.0 ‐ SUBJECT AND REFERENCES
1.1 ‐ STRUCTURE
2.0 ‐ EXISTING AND PROPOSED APPURTENANCES
3.0 ‐ CODES AND LOADING
4.0 ‐ STANDARD CONDITIONS FOR ENGINEERING SERVICES ON EXISTING
STRUCTURES
5.0 ‐ ANALYSIS AND ASSUMPTIONS
6.0 ‐ RESULTS AND CONCLUSION
APPENDICES
A ‐ SOFTWARE OUTPUT
Page |0 DESTEK ENGINEERING, LLC
5150 Stilesboro Road, Suite 510, Kennesaw, GA 30152 ‐Tel: (770) 693‐0835
Shalimar – Structural Analysis
1.0 SUBJECT AND REFERENCES
The purpose of this analysis is to evaluate the structural capacity of the existing 181.25 feet
tall monopole, located at 1250 N Eglin Pkwy, Shalimar, FL 32579, for the addition of wireless
telecommunication appurtenances proposed by Verizon Wireless.
The structural analysis is based on the following documentation provided to Destek
Engineering, LLC (Destek):
Structural Analysis Report prepared by FS Tan Land Surveyors & Consulting Engineers
Inc., dated 5/17/2011.
Final Antenna Design – Shalimar, provided by Verizon Wireless.
Site Photographs provided by PM&A
1.1 STRUCTURE
The structure is a 181.25 feet tall, 12‐sided tapered monopole which is attached to the
foundation with anchor bolts and a base plate. The pole is formed by the following sections:
SECTION LAP SPLICE (IN) SHAFT TOP DIA/BOT YIELD
LENGTH (FT) THICKNESS (IN) DIA (IN/IN) STRENGTH (KSI)
46.00 48.00 0.40 15.00/28.55 65
52.00 62.00 0.53 26.30/41.29 65
44.00 67.00 0.54 38.74/51.42 65
53.00 ‐ 0.60 48.73/64.00 65
2.0 EXISTING AND PROPOSED APPURTENANCES
Verizon Wireless is proposing the following changes on the monopole:
Existing Verizon Wireless appurtenance configuration
RAD CENTER (FT) ANTENNA & TMA MOUNT FEED LINES
175 (6) WPA‐80063‐8CF (3) T‐Arms (12) 1 5/8”
(3) LNX‐6515DS‐VTM
Proposed Verizon Wireless appurtenances
RAD CENTER (FT) ANTENNA & TMA MOUNT FEED LINES
175 (3) HBX‐6517DS‐VTM (3) T‐Arms
(3) E15Z09P94 TMAs
Page |1 DESTEK ENGINEERING, LLC
5150 Stilesboro Road, Suite 510, Kennesaw, GA 30152 ‐Tel: (770) 693‐0835
Shalimar – Structural Analysis
Final Verizon Wireless appurtenance configuration
RAD CENTER (FT) ANTENNA & TMA MOUNT FEED LINES
CARRIER
175 (6) WPA‐80063‐8CF (3) T‐Arms (12) 1 5/8”
(3) LNX‐6515DS‐VTM
(3) HBX‐6517DS‐VTM
(3) E15Z09P94 TMAs
Existing Appurtenances by Others
RAD CENTER (FT) ANTENNA & TMA MOUNT FEED LINES
CARRIER
181.25 (10) DB224 Low Profile (10) 1 1/4”
(2) DB810 Platform
142.5 (6) X7C‐FRO‐440 Low Profile (6) 1 5/8”
Platform
137 (9) LPA‐7060 (3) T‐Arms (9) 7/8”
3.0 CODES AND LOADING
The monopole was analyzed per 2010 Florida Building Code, which references ANSI/TIA/EIA‐
222‐G‐1. The following wind loading was used in compliance with the standard for Okaloosa
County.
Ultimate Design Wind speed at the site is 143 mph (interpolated between the
contours). Basic wind speed (Wo) without ice = 143*(0.6)1/2=111 mph
Service wind speed 60 mph
Exposure D
Structure Class II, Importance Factor = 1.0
The following load combinations were used with wind blowing at 0o, 60o and 90o, measured
from a line normal to the face of the monopole.
1.2D +1.6Wo
0.9D +1.6Wo
1.2D + 1.0Di + 1.0Wi
D: Dead Load of structure and appurtenances
Wo: Wind Load, without ice
Wi: Wind Load, with ice
Di: Weight of ice due to factored ice thickness
Page |2 DESTEK ENGINEERING, LLC
5150 Stilesboro Road, Suite 510, Kennesaw, GA 30152 ‐Tel: (770) 693‐0835
Shalimar – Structural Analysis
4.0 STANDARD CONDITIONS FOR ENGINEERING SERVICES ON EXISTING STRUCTURES
The analysis is based on the information provided to Destek and is assumed to be current
and correct. Unless otherwise noted, the structure is assumed to be in good condition, free
of defects and can achieve theoretical strength.
It is assumed that the structure has been maintained and shall be maintained during its
service. The superstructure and the foundation system are assumed to be designed with
proper engineering practice and fabricated, constructed and erected in accordance with the
design documents. Destek will accept no liability which may arise due to any existing
deficiency in design, material, fabrication, erection, construction, etc. or lack of
maintenance.
The analysis does not include a qualification of the mounts attached on the structure or their
connections. The analysis is performed to verify the capacity of the main structural
members, which is the current practice in the tower industry.
The analysis results presented in this report are only applicable for the previously mentioned
existing and proposed appurtenances. Any deviation of the appurtenances and
appurtenance placement will require Destek to generate an additional structural analysis.
Additionally, the proposed linear appurtenances should be placed per recommendations of
this report.
5.0 ANALYSIS AND ASSUMPTIONS
The monopole was analyzed by utilizing Risa Tower, a non‐linear, 3‐Dimensional, finite
element analysis software package, a product of Risa Technologies. Software output for this
analysis is provided in Appendix‐A of this report.
The shaft thicknesses are based on field measurements (listed in the referenced analysis),
which do not appear to be the typical industry practice. We recommend these values to be
verified.
The following was assumed based on common industry practice:
Shaft Steel: 65 ksi yield strength
Base Plate Steel: 60 ksi yield strength
Anchor Bolts: 75 ksi yield strength.
Page |3 DESTEK ENGINEERING, LLC
5150 Stilesboro Road, Suite 510, Kennesaw, GA 30152 ‐Tel: (770) 693‐0835
Shalimar – Structural Analysis
6.0 RESULTS AND CONCLUSION
Based on a feasibility analysis per ANSI/TIA‐222‐G‐1, the existing monopole is found to have
adequate structural capacity for the proposed loading by Verizon Wireless. As a maximum,
base plate is stressed to 90% of capacity. Monopole shafts are stressed to maximum 89% of
capacity. Anchor bolts are stressed below capacity as well.
Information regarding the existing soils and foundation system was not available at the time
of this analysis, thus a foundation analysis could not be completed.
Reactions Comparison
Maximums Destek Analysis FS Tan Analysis
Moment (kip*ft) 9542 9344
Shear (kips) 88.3 105.8
Should you have any questions about this report, please contact Ahmet Colakoglu at (770)
693‐0835 or acolakoglu@destekengineering.com.
Sincerely,
Destek Engineering, LLC
10‐7‐2013
Ahmet Colakoglu, P.E.
Florida Professional Engineer
License No: 69688
Page |4 DESTEK ENGINEERING, LLC
5150 Stilesboro Road, Suite 510, Kennesaw, GA 30152 ‐Tel: (770) 693‐0835
APPENDIX A
SOFTWARE OUTPUT
DB810K
DB224
LNX-6515DS-VTM
HBX-6517DS-VTM
Commscope
(2)
Low
T-Arm
(3) Antel
LPA-70060-8CF-EDIN-X
X7C-FRO-440