existing MDR FLUM designation also
permits 15 gupa.
E. HEIGHT LIMIT
The maximum building height shall not exceed 45 feet; measured from the adjacent
crown of road to the ceiling of the top floor of the building. Roof structures and
architectural elements may project up to 15 feet above the ceiling of the highest floor.
F. OFF- STREET PARKING
The Multi- family residences shall require 2 parking spaces per apartment unit and
0. 10 bicycle spaces per required parking space. The 2, 674 square foot clubhouse and
leasing office shall provide 1 parking space per 400 square feet of floor area. Handicap
accessible parking spaces shall be in compliance with ADA standards.
G. LANDSCAPE STANDARDS
Landscape standards shall be in compliance with the city' s Code of Ordinances. A
10 foot wide perimeter landscape strip shall be provided along all property lines.
H. BUILDING ORIENTATIONS AND PROFILE
The buildings shall address the streetscape with porches that face the streets to help
create a walkable community. Interior sidewalks shall connect to the existing public
sidewalks located along Carson Drive and Third Street. The buildings will offer
attractive pedestrian- scale features detailed by the architectural style of the buildings
Southern Coastal Craftsman). proposed external building materials shall be
The
cementious siding with stone veneer accents. The roof material shall be galvanized
8
Sound Side
Planned Unit Development
metal and the windows shall be insulated, single hung and impact resistant in
compliance with the city's adopted building code.
I. FENCE REQUIREMENTS
Fence standards shall comply with the city' s Code of Ordinances regarding height,
materials and placement. Any installed fencing must provide gates where interior
sidewalks connect to existing public sidewalks. Gates must also be provided for
sidewalks connecting to the church property at 34 Carson Drive, SE.
J. UTILITIES
Allpotable water, sanitary sewer, solid waste and other utilities shall be designed,
approved, and installed in accordance with city requirements.
Available Utility Infonnation:
Potable Water: City of Fort Walton Beach
Sanitary Sewer: City of Fort Walton Beach
Sanitation: City of Fort Walton Beach
Telephone: Sprint/ Southern Bell/ AT&T
Electrical Service: Gulf Power Company
Gas Service: Okaloosa Gas District
1V Cable: Cox Communications
K. STORMWATER MANAGEMENT
Stonnwater management shall be in compliance with the City of Fort Walton Beach
standards.
L. FLoOD ZONE INFORMATION
The subject property is located in Zone " X" per Flood Insurance Rate Map ( FIRM) of
Okaloosa, Florida, Community Panel No. 12091C0461H, Dated December 06, 2002.
Therefore, the development is not located within a 100 year special flood hazard area.
IV. LIMITATIONS TO REVISIONS OF LDC
Any adopted changes made in the City's Land Development Code after the adoption of
Ordinance 1792 and the Sound Side, a Planned Unit Development, shall not affect the
development standards of this PUD.
9
Sound Side
Planned Unit Development
v. CONTENTS OF PRELIMINARY AND FINAL DEVELOPMENT PLANS
A. CONTENTS OF PRELIMINARY PLAN
Legal Description
A PORTION OF LAND LYING IN SECTION 13, TOWNSHIP 2 SOUTH, RANGE 24 WEST,
OKALOOSA COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS
FOLLOWS:
COMMENCE AT THE SOUTHEAST CORNER OF LOT 1, BLOCK " A" CHATELAINE
ESTATES, AS RECORDED IN PLAT BOOK 17, PAGE 85, OKALOOSA COUNTY,
FLORIDA, THENCE NORTH 03 DEGREES 05 MINUTES 12 SECONDS WEST, A
DISTANCE OF 25. 83 FEET AND THE POINT OF BEGINNING; THENCE CONTINUE
NORTH 03 DEGREES 05 MINUTES 12 SECONDS WEST, A DISTANCE OF 1000. 00 FEET;
THENCE NORTH 86 DEGREES 54 MINUTES 26 SECONDS EAST, A DISTANCE OF
616.40 FEET; THENCE SOUTH 02 DEGREES 57 MINUTES 48 SECONDS EAST, ALONG
THE WEST RIGHT- OF-WAY LINE OF CARSON DRIVE ( 60' RIGHT- OF- WAY), A
DISTANCE OF 450.49 FEET; THENCE SOUTH 87 DEGREES 08 MINUTES 53 SECONDS
WEST, A DISTANCE OF 215. 10 FEET; THENCE SOUTH 03 DEGREES 03 MINUTES 26
SECONDS EAST, A DISTANCE OF 150. 05 FEET; THENCE NORTH 86 DEGREES 51
MINUTES 43 SECONDS EAST, A DISTANCE OF 214. 88 FEET, TO SAID WEST RIGHT-
OF- WAY LINE OF CARSON DRIVE ( 60' RIGHT- OF- WAY); THENCE SOUTH 03
DEGREES 02 MINUTES 28 SECONDS EAST, ALONG SAID WEST RIGHT-OF- WAY
LINE, A DISTANCE OF 375. 64 FEET; TO A POINT OF CURVATURE; THENCE
SOUTHWESTERLY THROUGH A CURVE TURNING TO THE RIGHT WITH A RADIUS
OF 25. 00 FEET, HAVING A CENTRAL ANGLE OF 89 DEGREES 54 MINUTES 48
SECONDS AND AN ARC LENGTH OF 39. 23 FEET ( CHORD BEARING: SOUTH 41
DEGREES 57 MINUTES 24 SECONDS WEST, CHORD DISTANCE: 35. 33 FEET) TO THE
POINT OF TANGENCY; THENCE SOUTH 86 DEGREES 54 MINUTES 48 SECONDS
WEST, A DISTANCE OF 589. 84 FEET TO THE POINT OF BEGINNING. CONTAINING
13. 39 ACRES, MORE OR LESS.
Compatibility
The development and design standards for the Sound Side PUD ( Planned Unit
Development) are consistent with the Fort Walton Beach Community Redevelopment
Agency Plan' s design guidelines and standards. The CRA plan titled " Fort Walton
Beach Community Redevelopment Agency Plan - Final Draft June 2007" was utilized
as a model for the design and implementation of the PUD development plan.
Description of Physical Characteristics
For the description of physical characteristics of the proposed development, see
Section III.Development and Design Standards of this PUD document.
Assurances of Governing Ownership
A copy of the deed is provided in Appendix A.
10
Sound Side
Planned Unit Development
Phasing Schedule
The proposed project will be constructed in one phase. All tenants currently residing
at Germany Terrace are to be relocated by December 15, 2008. It is anticipate that
Sound Side will commence with construction on January 1, 2009 and be completed
by January 31, 2009. The demolition is to be completed in 30 days by January 31,
2009. Vertical construction will then begin on February 1, 2009. The first move- in
date for tenants will begin on October 1, 2009. All construction is estimated to be
completed by January 31, 2010.
B. DEFINITIVE MAPs AND GRAPIUC ILLUSTRATIONS
A vicinity sketch showing the existing zoning and future land use of the property is
provided within Appendix J and Appendix K, respectively.
Existing Zoning and Existing Land Use
The existing zoning for the Sound Side development is R-2 Multiple Family. The
existing land use is 50 multi- family residential dwelling units; one metal maintenance
shed building, one wood shed, and two NAACP buildings. The future land use is
medium density residential. See Appendix J for Existing Zoning and Appendix K for
Future Land Use maps of the property.
Preliminary Site Plan
The development will consist of 200 multi- family apartment units and a 2, 674 square
foot clubhouse I leasing office. Provided in Appendix F, Site Improvement Plans,
Sheet C- 2 is a site plan of the proposed Sound Side development.
Location and Availability of all Utilities
The potable water for the proposed Sound Side development will connect to the
existing 6- inch watermain along the east side of Carson Drive in two places to have a
looped water system.
One portion of the gravity sewer will tie into existing manhole located on the
an
proposed Sound Side property at the northeastern edge of the property line. The
second portion of the gravity sewer will tie into an existing manhole located within the
right-of-way of Third Street at the southern edge of the property line. The final portion
of the gravity sewer will tie into another existing manhole located within the right -of-
way of Third Street at the southern edge of the property line.
Other available Utility Information is as follows:
Potable Water: City of Fort Walton Beach
Sanitary Sewer: City of Fort Walton Beach
Sanitation: City of Fort Walton Beach
Telephone: SprintlSouthern BellIAT&T
Electrical Service: Gulf Power Company
Gas Service: Okaloosa Gas District
11
Sound Side
Planned Unit Development
IV Cable: Cox Communications
Provided in Appendix F, Site Improvement Plans, Sheet C- 6 is utility plan showing the
location of proposed utilities for the Sound Side development.
Existing Topographical Contours
The existing site is relatively flat with little topographic relief. The contours range from
13 to 18 feet. Provided in Appendix B is a survey of the existing land.
General Architectural Features
The Architectural style of the Sound Side development is influenced by the " Coastal
Vernacular" style evident in the early development of the Florida Coast. The lapped
siding, column detailing, and standing seam roof are all elements of the Coastal
Architecture of early Florida development.
The roof lines, gables, column details, window details, lap siding, stonework, and
standing seam metal roof all come together to form a pleasing Architectural Style that
looks like it belongs on the Florida Coast. Since the style is patterned after the
traditional past, the style will remain timeless and not become dated.
Provided in the Appendix G are side elevations for each building within the Sound Side
development.
VI. CONTENTS OF FINAL DEVELOPMENT PLANS
A. FIELD SURVEY AND LEGAL DESCRIPTION
The final development plan will consist of the following legal description. In Appendix
E, there is a copy of the final development plat.
A PORTION OF LAND LYING IN SECTION 13, TOWNSHIP 2 SOUTH, RANGE 24 WEST,
OKALOOSA COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS
FOLLOWS:
COMMENCE AT THE SOUTHEAST CORNER OF LOT 1, BLOCK " A" CHATELAINE
ESTATES, AS RECORDED IN PLAT BOOK 17, PAGE 85, OKALOOSA COUNTY,
FLORIDA, THENCE NORTH 03 DEGREES 05 MINUTES 12 SECONDS WEST, A
DISTANCE OF 25. 83 FEET AND THE POINT OF BEGINNING; THENCE CONTINUE
NORTH 03 DEGREES 05 MINUTES 12 SECONDS WEST, A DISTANCE OF 1000. 00 FEET;
THENCE NORTH 86 DEGREES 54 MINUTES 26 SECONDS EAST, A DISTANCE OF
616.40 FEET; THENCE SOUTH 02 DEGREES 57 MINUTES 48 SECONDS EAST, ALONG
THE WEST RIGHT- OF- WAY LINE OF CARSON DRIVE ( 60' RIGHT- OF- WAY), A
DISTANCE OF 450.49 FEET; THENCE SOUTH 87 DEGREES